/195M (TNB)
USER’S MANUAL
Revised: 30 Jan 2018
9 of 10
Software Commands
Listed below in alphabetical order are the definitions of the ESTeem software commands. All software commands
are entered lowercase.
? or help
help
Displays the modem information and sub help menus.
help all
Displays all commands switches and arguments.
help radio
Displays radio commands switches and arguments.
help interface
Displays interface commands switches and arguments.
help setup
Displays setup commands switches and arguments.
help system
Displays system commands switches and arguments.
cert
This command will display the FCC ID and model number of the amplifier.
indent (Any alphanumeric input)
The command sets the ID field for the amplifier. This can be set to any alphanumeric value such as site name, location or
serial number. This value will be displayed in the Discovery Utility under ID (see figure 6)
pcbtemp
This command will measure the internal temperature of the amplifier. The temperature will be displayed in both
Celsius and Fahrenheit.
reflect (0-2000)
This software command will set the maximum reflection threshold before the amplifier will stop operation. The ratio number
will change based upon hardware conditions, environmental conditions and overall power output, but the ratio number is
not directly related to a percentage or power value. It is best used as a long term indicator of the heath of the transmission
system. As the number approaches 0 (lower ration numbers) the higher the reflected power is detected. If the reflect
command is set to 0, this feature will be turned off.
Factory default = 0