background image

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

EED4100S
EED4300S
EED4400S
TEDS740P

TEDS840P
TEDX340R
TEDX540R
TEDX640P

Electrical:

A four-wire or three-wire, single phase,

120/240-volt, 60 Hz, AC-only, electrical supply (or
120/208-volt electrical supply, if specified on the
serial/rating plate) is required on a separate 30 amp
circuit, fused on both sides of the line. Use 10
gauge solid copper wire. A time-delay fuse or circuit
breaker is recommended.

Exhaust venting:

Exhaust your dryer to the

outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 8577187

08-10-06

A. Small opening side-swing door
B. Large opening side-swing door

C. Wide opening side-swing door
D. Wide opening hamper door

43

³⁄₈

"

(110 cm)

*26"

(66 cm)

29"

(73.66 cm)

A

15¼"

(38.74 cm) 43

³⁄₈

"

(110 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

B

22 ¾"

(57.8 cm)

43

³⁄₈

"

(110 cm)

13 ¾"

(34.9 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

D

43

³⁄₈

"

(110 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

C

22 ¾"

(57.8 cm)

A

B

C

    18"
(45.7 cm)

    0"*
(0 cm)

       29"
(73.66 cm)

        0"*
(0 cm)

        0"*
    (0 cm)

14" max.
(35.6cm)

   27¾"
(70.5 cm)

5½"
 (14 cm)

  48 in.  
(310 cm  )

2

2

  24 in.
(155 cm  )

2

2

       3"
(7.6 cm)

       3"
(7.6 cm)

*Additional spacing recommended

A. Recessed area
B. Side view - closet or confined area

C. Closet door with vents

For closet installation with a
door, minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
air openings are acceptable.

Electric Dryer

* Most installations require a

minimum 5

¹⁄₂

" (14 cm)

clearance behind the dryer for
the exhaust vent with elbow.

NOTE: 

Side and bottom exhaust installations have a 90

°

 turn 

inside the dryer. To determine maximum exhaust length, add one 
90

°

 turn to the chart.

Number of 
90

°

 turns 

or elbows

Type of
vent

Box or 
Louvered 
hoods

Angled
hoods

0

Rigid

 metal

Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid

 metal

Flexible metal

54 ft (16.5 m) 
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid

 metal

Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11.6 m)
19 ft (5.8 m)

3

Rigid

 metal

Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (8.8 m)
17 ft (5.2 m)

4

Rigid

 metal

Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

Select the route that will provide the straightest and most direct path
outdoors.  Plan the installation to use the fewest number of elbows and turns.
Avoid making 90° turns.  

Do not use vent runs longer than specified in vent length chart.

Determine the number of elbows you will need.

A. Louvered hood style

B. Box hood style

      4"
(10.2 cm)

      4"
(10.2 cm)

A

B

  4"

(10.2 cm)

2.5"

(6.4 cm)

Recommended hood styles

Angled hood style is

acceptable.