10
Temporary Safety Jumpers
For the highest level of safety, the Estate Swing systems are set up with Normally Closed safety
terminals. This means that in order for the gate opener to move these terminals must be closed
either through a safety device (recommended) or with jumpers. Temporary safety jumpers are in-
stalled in the factory
It is recommended not to use any accessories until setup and programming is complete.
NOTE: If not using safety devices the temporary safety jumper must remain in. In order for
the gate operator to move. Also in order for safety devices to function the safety jumpers
must be removed.
Troubleshooting tip:
If the gate will only open and will not close - the safety jumper is not making a connection
between the two terminals. Even with a jumper in place, sometimes metal or wire loses its
conductivity for various reasons. Please try to replace this jumper and see if the problem is
resolved.