Essilor CORNEA 550 Скачать руководство пользователя страница 11

Warning

The user must take into account the potentially harmful effects to the environment or human 
health due the improper disposal of the equipment or of parts of it.

To prevent the release of hazardous substances into the environment and to promote conservation of natural
resources, the manufacturer, in case the user wishes to dispose of the device used at the end of its useful
life, facilitates the possibility of its reuse and the recovery and recycling of the materials contained therein.

The graphic symbol shown in the figure is applied on the equipment's label.

It reminds that all electrical and electronic equipment must be collected and disposed of 
separately at their end-of-life.

In the case of disposal of the device, specific provisions of European and national law apply, and provide
that:

The device shall not be disposed of as urban waste, it shall be collected separately, by contacting a
company specializing in the disposal of electrical/electronic equipment or the public authorities
responsible for waste management.

In the event that a new piece of equipment is purchased from the same manufacturer to replace an
old one placed on the market before 13 August 2005, equivalent and with the same functions of the
new equipment, the distributor or manufacturer is legally required to collect the old piece of
equipment.

If the user wants to get rid of a used piece of equipment, placed on the market after 13 August 2005,
the distributor or manufacturer is legally required to collect it.

By joining the specific technological waste disposal consortium, the manufacturer shall take care of
the handling, recovery and/or disposal of the old equipment collected, at its own charge.

The manufacturer will provide the users with any information regarding the hazardous substances contained
in the device and on the recovery and recycling of said substances, as well as on the possible reuse of the
used device.

Violations shall be punished by the current legislation with serious administrative sanctions.

U

SER

 

MANUAL

> I. I

NTRODUCTION

13

Cornea550 - Corneal Topographer > V4 - 12-2017

Содержание CORNEA 550

Страница 1: ...User manual...

Страница 2: ...a Classification 10 b Environmental conditions 11 c Warranty 11 4 Safety precautions 12 5 Disposal at the end of life 13 II SUPPLY PACKAGE 15 1 Parts identification 17 III ROUTINE MAINTENANCE 19 IV U...

Страница 3: ...I INTRODUCTION...

Страница 4: ...dedikert applikasjon O manual do usu rio completo est dispon vel na rea web do cliente Para acessar scanear o c digo QR abaixo usando a respetiva aplica o 1 GENERAL WARNINGS These instructions descri...

Страница 5: ...ct and separate disposal of electrical and electronic equipment at the end of their useful life according to 2012 19 EU Date of manufacturing Manufacturer Class II device a Symbols marked on the instr...

Страница 6: ...e allows the following Corneal topography module Assisted manual acquisition Advanced ring editing system allowing editing edge position to guarantee proper reconstruction also on particularly distort...

Страница 7: ...re during dilation Apply the measurements previously listed to the calculation of the corneal wavefront and visualize the pupil in different conditions on the topographic map Videokeratoscopy module E...

Страница 8: ...g are not made in accordance with the instructions and precautions given in this manual The device is not used in accordance with the instructions and precautions in this manual Spare parts and access...

Страница 9: ...vice includes non electromedical appliances personal computer monitor etc The resulting system is in any case tested in accordance with EN 60601 1 standards Since the unit in question can include othe...

Страница 10: ...m remote stations through the connected cables The use of data transfer devices ensuring GALVANIC ISOLATION may be necessary Manufacturer shall not be held liable in relation to the patient and operat...

Страница 11: ...of electrical electronic equipment or the public authorities responsible for waste management In the event that a new piece of equipment is purchased from the same manufacturer to replace an old one...

Страница 12: ...II SUPPLY PACKAGE...

Страница 13: ...z 0 9A OUTPUT 24Vdc 2A 3 AnaEyes software The system is supplied with the following accessories Two guards for the slide guides One protection cover One set of Allen wrenches One set of chinrest paper...

Страница 14: ...guides 8 Output 9 Geared wheels 10 Chinrest support 11 Patient s handle 12 Chinrest 13 Headrest 14 Chinrest module 15 Calibration set 16 Instrument power supply cable 17 Optical switching data namepla...

Страница 15: ...III ROUTINE MAINTENANCE...

Страница 16: ...ust Dust accumulating on the device must be regularly removed with a soft cloth or blower Other maintenance operations repairs components replacement assessment of internal components etc fall within...

Страница 17: ...IV USAGE...

Страница 18: ...exam mode among KERATOSCOPY VIDEOKERATOSCOPY PUPILLOGRAPHY MEIBOGRAPHY TEAR FILM Move onto the instrument Move the joystick to centre the eye on the display refocus placing the joystick perpendicular...

Страница 19: ...tric shock this device must only be connected to a power supply system with protective earthing For isolation from the mains condition of complete safety the computer power cable must be disconnected...

Страница 20: ...V TECHNICAL FEATURES...

Страница 21: ...pply Through 24V DC external power supply unit Input power supply unit specifications INPUT 100 240Vac 50 60Hz 0 9A OUTPUT 24Vdc 2A Power cable technical specifications Four core cable three cores wit...

Страница 22: ...VI GUIDANCE AND MANUFACTURER S DECLARATION...

Страница 23: ...F energy only for its internal function Therefore its emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emission CISPR 11 Class B The CORNEA550 is s...

Страница 24: ...al environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Voltage dips Short interruptions and voltage variations on power supply input lines I...

Страница 25: ...nce d 1 167 P d 1 167 P 80 MHz to 800 MHz d 2 333 P 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the r...

Страница 26: ...VII APPENDIX...

Страница 27: ...e on the base plate and insert the screws supplied Fix the top to the bottom by tightening the four socket head screws 2 Unscrew the two socket head screws under the chinrest Insert the screws in the...

Страница 28: ...USER MANUAL VII APPENDIX 33 Cornea550 Corneal Topographer V4 12 2017...

Страница 29: ...Essilor Instruments USA 8600 W Catalpa Avenue Suite 703 Chicago IL 60656 Phone 855 393 4647 Email info essilorinstrumentsusa com www essilorinstrumentsusa com...

Отзывы: