Essick SI-500S Скачать руководство пользователя страница 2

Evaporative Cooling 

Evaporative cooling uses the principle of evaporation to lower the air temperature.  Hot, dry air is passed through wetted 
filters and is converted to refreshingly cooled air.  Essick Coolers make the best use of the evaporative process by 
controlling the flow of water, spreading the water evenly over the filters, and keeping a steady stream of cooled air 
entering your home.  It is exhausted out open windows or doors, carrying heat, smoke and odors along with it. Essick 
evaporative coolers are 80% less costly to operate than refrigerated air conditioners. 

 

Cautions: 

To prevent harm to yourself and others, and to avoid damage to your cooler, PLEASE follow these guidelines. 

 

SAFETY GUIDE LINES & CAUTIONS 

When Installing 

When Operating 

When Servicing 

Make sure that unit is installed on a sound 
structure that will support the full operating 
weight of the cooler.  See page 5. 

Make sure that cooler circuit is equipped with a 
(slow blow) breaker large enough to support the 
full amperage of the cooler. 

Be sure to disconnect unit from power 
source before servicing.  If not, it can be 
turned on from inside the house and start 
unexpectedly. 

Before attempting to transport cooler to the roof.  
Separate fan section from wet section to reduce 
weight.  Always plan a safe method of 
transporting cooler to installation site without 
damage to the cooler or injury to yourself. 

To reduce the risk of fire or electrical shock, DO 
NOT use this fan with any Solid-state speed 
control device. 

Never drain water onto your roof.  Water 
residue could cause you to slip or may stain 
your roof. 

Do Not connect power to cooler before 
installation is complete. 
Wear gloves and protective eyewear when 
installing or servicing. 

This cooler is equipped with an automatic 
thermally protected motor.  If it shuts off on its 
own for any reason, it can restart without 
warning. 

If the motor shuts off because of thermal 
overload, check into the problem 
immediately.  If allowed to continue, 
permanent damage will occur. 

 

Tools and supplies needed for installation 

 

Pliers 

 

Screwdrivers 

 

Adjustable wrenches 

 

Tubing cutter 

 

5/32 hex key wrench 

 

Level 

 

Electric drill 

 

Drill bits 

 

Hammer 

 

Duct tape 

 

Caulk 

 

Sheet metal screws 

 

ECR-6 wall switch 

 

Safety glasses 

 

Wiring supplies – It is recommended that a licensed 
electrician do all electrical work. 

 

Ductwork – A local sheet metal shop can supply ductwork. 

 

¼” water line 

 

Saddle valve or faucet adapter 

 

Roof stand (if cooler is roof mounted) 

 

Roof flashing and pitch 

 

Mounting 

1. Prepare duct to fit model used (500 series coolers 17 ¾” square; 700 series 19 ¾” square). 
2. Cut opening in wall or roof to fit duct.  If wall studs or roof joists are cut, reinforce them. 
3. Mount the duct in the opening.  The duct will fit inside the cooler opening.  The duct length from roof to bottom of cooler 

should be a minimum of 4” at the closest point, so there is access to the water drain. 

4. Install flashing around roof opening to prevent water entry.  Use pitch to seal the seams. 
5. Measure cooler and layout mounting location. 
6. Mount cooler to stand or pad.  Cooler must be level front to back and left to right.  Note: It is best that the fan section 

end of the cooler face up the roof to achieve a lower profile and allow better access to the drain. 

7. Be sure to securely fasten all four corners of cooler to stand or pad. 
8. Caulk duct to the cooler to prevent air leakage. 

 

Motor mounting 

Warning: Do Not energize the cooler until the installation is complete. 

1.  Place the motor into the cradles.  Be sure that the cradles fit into the groove in the 

motor grommets. 

2.  Secure with the saddle clamps provided in the installation package.  

DO NOT 

OVERTIGHTEN.

 

 

Содержание SI-500S

Страница 1: ...12 SI 700D12 SINGLE INLET Horizontal And Down Discharge Evaporative Air Cooler Read Save This Instruction Manual Our Mission We Will Respond to Our Customers With High Quality Products and Service Whi...

Страница 2: ...This cooler is equipped with an automatic thermally protected motor If it shuts off on its own for any reason it can restart without warning If the motor shuts off because of thermal overload check i...

Страница 3: ...the zero position 3 Turn the outside jaw of the pulley counterclockwise 3 full turns Align set screw with a flat on the threaded portion of the pulley and tighten This step will ensure that your cool...

Страница 4: ...r end of tubing Insert the tubing into float valve and tighten Compression Nut to secure Reservoir Ferrule Faucet Note Tightening a compression fitting will cause that fitting to leak It is best to se...

Страница 5: ...e diameter of the pulley in order to adjust the belt tension Lubrication Lube the oil cups on the blower bearing Use SAE20 or SAE30 Non Detergent oil Oil the blower motor only if oil holes exist End o...

Страница 6: ...Replacement Parts 6...

Страница 7: ...70116 70116 70116 22 Water distributor Distribuidor del agua 1 70043 70043 70043 70043 23 Pad media set Juego de filtros 1 70054 70054 70055 70055 24 Water shield set Juego de protectores del agua 1 7...

Страница 8: ...parts as follows Cabinet components for one year from date of installation Evaporative media for five years from date of installation Exclusions from this warranty Essick Air Products is not responsib...

Отзывы: