background image

 

 

 

How Your Humidifier Works 

Your new Essick Air® Evaporative 
humidifier is designed to satisfy home 
humidity requirements through the 
principle of evaporation of water in the 
air. 

Once the wick becomes saturated, air 
is drawn in, passes through the wick 
and moisture is absorbed into the air.  
All evaporation occurs in the 
humidifier so any residue remains in 
the wick. This natural process of 
evaporation creates no white dust like 
some other humidifiers. 

 

 

Set Up and Location 

1) 

Unpack humidifier from carton and remove all packaging material, wick, etc. 
from box.

 

 

2) 

Place humidifier on a flat level surface. Position the humidifier where the most 
humidity is needed or where the most air will be circulated throughout the 
house such as near a cold air return. If the unit is positioned close to a window, 
condensation may form on the window pane. If this occurs the unit should be 
repositioned in another location.  

NOTE:

 

Due to release of cool, moist air from humidifier, it is best to direct air 

away from thermostat and hot air registers, and to position humidifier next to 
an inside wall. Unit should not be placed where cold air from outside walls or 
warm air from a hot air register blows directly on it. 

3) 

Place the humidifier at least 4 inches from the wall. 

WARNING

For your own safety, do not use humidifier if any parts are damaged or missing 

CAUTION: Do NOT position the unit directly in front of a hot air duct or radiator. 
Do NOT place on soft carpet. We suggest placing the unit on a table or on a 
bookshelf. 

 

IMPORTANT: Water damage may 
result if condensation starts to form 
on windows or walls. Humidity SET 
point should be lowered until 
condensation no longer forms. We 
recommend room humidity levels do 
not exceed 50%. 

 

When Outdoor 

Temperature is

             

C

 

Recommended 

Indoor Relative 

Humidity (RH) is 

-10° 

  2° 
10° 

  20°*  

   -24° 
   -18° 
   -12° 
    -6°* 

20% 
25% 
30% 
35% 

* or higher

 

Содержание E35 000 E35

Страница 1: ...IFIER MODEL E35 000 Table top 2 speed Fan Portable for Versatility Ideal for Home Office Dorms or Vacation Spots Adjustable Humidity Level Analog Hygrometer Bucket Fill Design Removable Dishwasher Saf...

Страница 2: ...er put the electric cord under rugs near heat registers radiators stoves or heaters 3 Always unplug the unit before moving cleaning or removing the fan assembly section from the humidifier or whenever...

Страница 3: ...ls Analog ETL Listed Yes Volts 120 Hertz 60 Watts 90 Based on an area with average insulation and an 8 ceiling height Replacement Parts Available For Purchase Description Part Number Chassis Entire to...

Страница 4: ...rm on the window pane If this occurs the unit should be repositioned in another location NOTE Due to release of cool moist air from humidifier it is best to direct air away from thermostat and hot air...

Страница 5: ...ning on the humidifier If you have only softened water available in your home you can use it but you will notice a build up of minerals on the evaporative wicks much sooner Base capacity is 2 0 gallon...

Страница 6: ...plays the room humidity NOTE If excessive condensation occurs reduce fan to a lower speed setting Care and Maintenance Cleaning your humidifier regularly helps eliminate odors bacterial and fungal gro...

Страница 7: ...f base with a soft brush Dampen soft cloth with white vinegar and wipe out base to remove scale 7 Rinse base thoroughly with fresh water and remove scale and cleaning solution Disinfecting Base 8 Fill...

Страница 8: ...MAXIMUM EXTENT PERMITTED BY LAW IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS EXPRESS OR IMPLIED ARISING BY OPERATION OF LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION MERCHANTABILITY...

Страница 9: ...des Port til para mayor Versatilidad Ideal para el Hogar Oficina Dormitorios y Locales de Vacaciones F cil de Limpiar Higr metro Anal gico Incorporado Dise o de llenado del dep sito Base segura para l...

Страница 10: ...ras cerca de fuentes de calor radiadores cocinas o calentadores 3 Siempre desenchufe el humidificador antes de moverlo antes de limpiarlo o cada vez que el humidificador no est funcionando 4 Mantenga...

Страница 11: ...l Registrado por ETL Si Voltios 120 Hertz 60 Watts 90 Basado en una superficie con aislamiento promedio y una altura de cielorraso de 8 pies Piezas De Repuesto Disponibles Para Compra Descripci n N o...

Страница 12: ...o Si se coloca la unidad cerca de una ventana se puede formar condensaci n en el vidrio de la ventana Si esto ocurre se debe colocar la unidad en otro lugar OBSERVACI N Debido a que el humidificador l...

Страница 13: ...toma el ctrica Si s lo tiene agua blanda en su casa puede usarla pero notar una acumulaci n m s r pida de minerales en las mechas evaporadoras La capacidad de la base es de 2 galones NO EXCEDA EL L MI...

Страница 14: ...te OBSERVACI N Si ocurre una condensaci n excesiva reduzca la velocidad del ventilador a una velocidad m s baja Cuidados y Mantenimiento Limpiar su humidificador regularmente ayuda a eliminar olores y...

Страница 15: ...ase con un cepillo blando Humedezca un pa o suave con vinagre blanco y frote la base para retirar el sarro 7 Enjuague la base cuidadosamente con agua limpia y retire el sarro y la soluci n de limpieza...

Страница 16: ...DO PARA USO COMERCIAL LA PRESENTE ES LA NICA GARANT A QUE OFRECE EL FABRICANTE CON RESPECTO A LOS PRODUCTOS Y HASTA EL GRADO M XIMO PERMITIDO POR LA LEY REEMPLAZA A CUALQUIER OTRA GARANT A POR ESCRITO...

Страница 17: ...t Id al pour la maison le bureau les r sidences universitaires ou les lieux de vacances Facile nettoyer Hygrom tre analogique int gr Conception remplissage de la base Base amovible lavable au lave vai...

Страница 18: ...air d un radiateur d un four ou d un appareil de chauffage 3 Toujours d brancher l humidificateur avant de le d placer Enlever le syst me de ventilation avant de nettoyer ou de faire r parer l humidif...

Страница 19: ...giques ETL mentionn s Oui Volts 120 Hertz 60 Watts 90 Bas e sur un espace isolation moyenne et une hauteur de plafond de 2 50m Pi ces d tach es disponibles l achat Description N de piece Ch ssis sauf...

Страница 20: ...rs NOTE Comme l appareil rend de l air froid et humide il vaut mieux le placer loin des thermostats ou indicateurs de temp rature le mettre par exemple pr s d un mur L unit ne devrait pas tre plac e u...

Страница 21: ...gicle sur le ch ssis laissez s cher avant de rebrancher Si l eau du robinet est adoucie vous remarquerez la formation d un mas de min raux sur les m che La capacit du base est de 2 0 gallons NE PAS DE...

Страница 22: ...de meilleurs r sultats 1 Cette unit a deux vitesses de ventilation contr l es par la touche en bas droite 2 La touche pour le niveau d humidit est situ e dessus la touche de vitesse du ventilateur Aug...

Страница 23: ...contenu de la base dans l vier S cher avec une ponge 5 Remplir la base au niveau maximum MAX et ajouter 8 onces 1 tasse de vinaigre blanc Laisser tremper pendant 20 minutes puis vider 6 Brosser d lica...

Страница 24: ...CECI EST LA SEULE ET EXCLUSIVE GARANTIE DONN E PAR LE FABRICANT EN CE QUI CONCERNE LES PRODUITS ET DANS TOUTE LA MESURE AUTORIS E PAR LA LOI REMPLACE ET EXCLUT TOUTES AUTRES GARANTIES ET CONDITIONS E...

Отзывы: