Trouble-Shooting
Silver-Line SL-1218R
A) The unit will not start:
ü
Is the unit well connected into the outlet?
ü
Is the Reset button (Thermo-contact switch) on the front of the machine set?
ü
Are the plugs between the handle and the base unit well connected?
ü
Are the male and female plugs in good condition?
ü
Are the wires well connected to the switch on the handle?
ü
Are the wires well connected into the motor?
ü
Is the wire cord in good condition?
B) The unit stops suddenly:
ü
Check all points in section 1
ü
Is the thermo-contact switch operating properly?
ü
Is the switch on the handle in good and functional conditional?
ü
Is the capacitor of the motor in good and functional condition?
C) The plate of the unit is not oriented correctly with the casing:
ü
Are the rubber towers of the unit in good condition or broken off?
ü
Are the bolts in the towers broken?
D) The unit makes a humming sound without moving:
ü
Check all points in section 1.
ü
Is there an object caught between the internal plate and the casing?
ü
Is the motor capacitor in good and functional condition?
ü
Is the shaft of the motor in good condition?
E) The unit starts slowly before picking up it regular speed:
ü
Is the starting switch of the motor in good condition?
ü
Is the switch in good condition?
ü
Is the wire cord in good condition?
F) The machine pulls to one side too much:
ü
Check the
Thick (1”) White Nylon pad
for wear, flip the pad over and rotate it 180 degrees. Try the
machine to see if it will run properly.
ü
Change the
Thick (1”) White Nylon Pad