Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

The power supply is Double Insulated and does not 
require connection to an Earth circuit.

The LED units are Safety Extra Low Voltage and 
must not be earthed.

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

This system operates at Safety Extra Low Voltage 
(12V), via an LED driver. Never connect the light 
fittings directly to the mains without using the supplied 
LED driver.

The mains plug must be situated indoors (e.g. house, 
garage, shed) in order to protect it from the elements.

Do not exceed the LED driver load. LED drivers may 
require a minimum load to operate.

Always disconnect the plug from the mains when 
installing or maintaining this system.

This system contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

This product cannot be dimmed.

This product is rated at IP44 with IP20 indoor plug.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

Specification

The Kit contains:
• 1 x 12V IP67 LED driver with 3.2m cable and indoor IP20 BS plug
• 1 x 5m extension cable
• 10 x IP44 LED spike light fittings each with 1.5m of cable.
• 1 x End Cap
• 10 x Surface mountable fixing brackets
• 1 x Fixing Kit

Layout

•  Decide on the position of the luminaire. Depending 

on the location, an approved outdoor rated plug and 
socket may be required. Alternatively an approved 
outdoor rated external terminal block may be used.

•  Avoid locating any cables in positions that would 

cause a trip hazard. Position cables away from areas 
where they may be at risk from being cut, trapped or 
damaged.

•  Cables that are to be in walls and concealed 

underground must be protected using suitable 
conduit or plastic trunking.

•  The driver is rated at IP67 and can be positioned 

outdoors.

•  Each connector is rated at IP44 and can be 

positioned outdoors. 

•  The light units are rated at IP44.

•  Maximum distance between spike lights is 1500mm.

•  A maximum of 20 spike lights can be connected 

together.

•  Ensure the connectors are accessible for future 

maintenance.

•  Ensure that the ground is suitable for pushing the 

spikes into, and can support the luminaires. Do not 
install in very wet or boggy areas.

1) Do not plug-in at this stage.

2) After deciding the layout of the light fittings, ensure the cables are long enough to 

connect to the desired positions. Each head links to the next via the IP44 screw fit 
connector. 

3) See Fig. 1. Push the stem into the light fitting head and then push the stem into the 

spike. Push the assembled products into the ground.

4) Connect each spike light to the next in series by screwing the connectors together. See 

layout diagram below.

5) Use the supplied blanking plug to cover last socket which is not being used, to prevent 

water ingress.

6) Connect the 5m extension cable into the first socket.

7) Ensure all connections are tight. Plug into the mains socket and switch on

Installation - Spike light

1) Do not plug-in at this stage.

2) See. Fig. 2. Using the supplied surface mount 

bracket as a template, mark and drill the fixing hole. 
Take care not to damage any concealed wiring and 
pipes. Fix the mounting bracket to the wall using the 
supplied screw and wall plug.

3) Gently push the light fitting head into the mounting 

bracket and secure in position.

6) Connect the 5m extension cable into the first socket.

7) Ensure all connections are tight. Plug into the mains 

socket and switch on.

Installation - Surface mounting

Layout Diagram

Fig. 1

Fig. 2

I