3: Brick up and form the flueway. 

Build-up a masonry wall around 

the boiler, forming a smooth connection to the flue with no ledges 
where  debris  could  collect.  Fill   any  space  with  mortar-and-rubble.
(Shown part-completed)

4: Fit fireplace surround.  

Slot a ready-made fireplace surround in 

place, or build one up using brick, stone or other masonry or metal 
materials. Extra fixing, if needed, is through the screw holes shown.

5: Refit front and check thermostat: 

Bolt the door/front unit back in 

place, taking great care that the parts seal. Reassemble the interior 
fittings and check that the door closes and seals properly. Push the 
thermostat sensor fully into its pocket, securing it with a dab of fire 
cement. The thermostat is a delicate instrument and, although it is 
tested and set at the factory, it may need re-adjusting.

6:   Adjusting   the   thermostat:  

With   the   fire   cold,   the   thermostat 

sensor vial in place and the thermostat control turned to '1' the air 
closure 'damper' plate should be approximately 7 mm open.

HEATING CIRCUIT

The GreenSwitch is for connection to open-vented, indirect, water 
systems  

only

, with  a  maximum  working   pressure  of 2  bar.  Every 

installation must include:

A   pipe   thermostat   to  prevent  the   pump   running  if  boiler   flow 
temperature drops below c50°C. This prevents heat from stored 
hot water being dumped if the fire dies down and guards against 
condensation inside the boiler.

A   pipe   thermostat   set   at   about   90°C   to   run   the   pump   and 

dissipate heat in the event of boiler overheating, irrespective of 
how other controls are set.

Means to completely drain water from the system.

A   means   of   dissipating   surplus   heat,   such   a   permanently 
connected radiator or hot-water system.

Means   to   allow   steam   to   be   released   in   case   of   complete 
thermostat and electrical failure.

In addition, we recommend:

Radiators fitted with thermostatic valves.

An 'anti gravity' valve preventing circulation to upper radiators 
when the pump is not running.

A   room-temperature   thermostat   and   single-circuit   time-clock 
controlling the running of the circulating pump.

The diagram shown one possible arrangement.

MULTI-BOILER SYSTEMS  

with simultaneous  automatic control of 

the   GreenSwitch  

and

  gas,   oil,   cooker-boilers,   heat   stores,   combi-

boiler etc. can be achieved using an Esse Centraliser unit. Details 
are available separately.

COMMISSIONING  

The   installer   must   complete   the   notice   at   the 

beginning   of   this   document,   demonstrate   the   method   of   lighting, 
control and cleaning, and point out the safety requirements to the 
householder.

GETTING THE BEST FROM YOUR

Every fuel, chimney and condition of use is different. Only experience 
will   show   which   is   the   best   for   you.   We   suggest   trying   several 
different fuels, or mixtures, and different settings of the controls.

GREENSWITCH GETS VERY HOT- 

Use a glove or the tool supplied 

to manipulate hot parts and controls. 

LIGHTING

 After a period of non-use, do 

check   the   chimney   for   blockages   first! 
Empty   the   ashes.   Place   two   or   three 
firelighters close together, or screwed-up 
paper   covered   with   dry   sticks,   at   the 
back of the grate and light them. When 
they are  burning  well  gently fill the fire 
with   dry   fuel   to   the   level   shown.   Don't 
over-fill or allow fuel to touch the throat 
plate.

EMPTYING ASHES  

Use the tool to pull 

the de-ashing mechanism on the right-hand side of the fire back-and 
forth.   If   it   jams,   don't   force   it   but   wait   a   few   minutes   for   any 
obstructing fuel lump to burn away. Open the door and lift out the 
ashpan. Let ash cool before disposing in plastic bins. There is no 
need to empty every speck, but make sure that ash from mineral 
fuels never builds up so that it touches the underside of the grate, or 
the grate will melt. 

EXTENDED BURNING

 Allow the fire to burn down to a low, hot fire 

bed. Empty the ash and well fill with smaller pieces of hard fuel such 
as anthracite. 

CLEANING

  Wipe the   body when cool. Soot will condense on the 

window if the fuel is damp or if the fire operates at low outputs for 
long   periods.   Deposits   will   normally   burn-off   when   the   next   fast-
burning  cycle  comes  round, but persistent stains  can be removed 
with a household bleach spray cleaner when the fire is cold.

DOOR

  Your GreenSwitch is designed to be operated only with the 

door closed. Open the door slowly to minimise fumes emission.

AUTOMATIC CONTROL.

 Your GreenSwitch has three controls. 

3