BIOMASS / MINERAL FUEL
FIREPLACE INSET ROOMHEATER
WITH THERMOSTATIC BOILER
INSTALLATION AND OPERATING INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER!
Water
For use only with open-vented, indirect, water systems. Maximum pressure 2 bar. Can be
inter-connected with combi boilers & other heat systems using Esse Centraliser Unit.
Control System:
All-mechanical thermostatic air supply to fire in response to boiler temperature. No electrical
connections or parts. Can be controlled by time clocks, room thermostat etc.
Fireplace & Chimney:
For installation in masonry fireplace with a single dedicated chimney.
Minimum flue draught 14Pa
Clearance:
Physical space: 100mm around in-room parts. From combustibles: 225mm
Extended Burn:
Variable with fuel, heat demand and chimney conditions. Anthracite = c12 hrs
MAXIMUM PERFORMANCE With door closed,
burning dry fuel with flue draught of 14Pa
Biomass (Wood Logs)
(With type 395 Boiler)
Mineral Fuel ('Ancit')
(With type 395 Boiler)
Mean flue temperature: *
395 ºC
364 ºC
Flue gas flow:
8.52 g/sec
13.6 g/sec
Mean CO in flue (as if at 13% O2):
0.4%
0.12%
Efficiency: *
75.7 %
72.7 %
Total output from appliance: *
14.7 kW (50,443 Btu)
14.6 kW (49,802Btu)
Output to room:
3.6 kW (12,437 Btu)
2.8 kW (9,714Btu)
Output to water:
11.1 kW (38,006 Btu)
11.8 kW (40,088Btu)
Fuel per hour at maximum:
3.8 kg
2.4 kg
Maximum achieved at refuelling interval of:
1 hr
2hr
* NOTE: Figures are for heat from the appliance
only
. There will typically be additional, often substantial, heat gains
from the masonry of the fireplace and chimney, and consequent higher total efficiency. Total performance for a
particular building can be calculated by the method of EN13384
Manufactured by: Esse Engineering Ltd
Long Ing, Barnoldswick, Lancashire
BB18 6BN,
England
www.esse.com
This document, when completed by the installer, constitutes a 'Hearth Notice' for purposes of the England and Wales
Building Regulations 2000, (App. Doc. J4). It must be left with the householder and placed where it can easily be found.
APPLIANCE SERIAL NUMBER:
INSTALLED AT LOCATION:
BY:
EMERGENCY TELEPHONE:
SIGNED: DATE:
Who certifies that this installation is safe, has been demonstrated to the householder,
conforms with current building regulations and with these instructions
Flue Draught
measured on
commissioning:
Fuel used on
commissioning
TO FIND A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY SWEEP, CONTACT:
UK:
The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55 7AS Tel:0845-601-4406
www.solidfuel.co.uk
RoI:
Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959
www.fireplace.ie
1
Pa