BIOMASS / MINERAL FUEL

FIREPLACE INSET ROOMHEATER 

WITH THERMOSTATIC BOILER

INSTALLATION AND OPERATING INSTRUCTIONS

LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER!

 

Water 

For use only with open-vented, indirect, water systems. Maximum pressure 2 bar. Can be 
inter-connected with combi boilers & other heat systems using Esse Centraliser Unit.

Control System: 

All-mechanical thermostatic air supply to fire in response to boiler temperature. No electrical 
connections or parts. Can be controlled by time clocks, room thermostat etc.

Fireplace & Chimney: 

For installation in masonry fireplace with a single dedicated chimney. 
Minimum flue draught 14Pa

Clearance: 

Physical space: 100mm around in-room parts. From combustibles: 225mm 

Extended Burn: 

Variable with fuel, heat demand and chimney conditions. Anthracite = c12 hrs

MAXIMUM PERFORMANCE  With  door closed, 

burning dry fuel with flue draught of 14Pa

Biomass (Wood Logs)

(With type 395 Boiler)

Mineral Fuel ('Ancit')

(With type 395 Boiler)

Mean flue temperature: *

395 ºC

364 ºC 

Flue gas flow:

8.52 g/sec

13.6 g/sec

Mean CO in flue (as if at 13% O2):

 0.4%

0.12%

Efficiency: *

 75.7 %

72.7 %

Total output from appliance: *

14.7 kW (50,443 Btu)

14.6 kW (49,802Btu)

Output to room:

  3.6 kW (12,437 Btu)

2.8 kW (9,714Btu)

Output to water:

 11.1 kW (38,006 Btu)

11.8 kW (40,088Btu)

Fuel per hour at maximum:

3.8 kg

2.4 kg

Maximum achieved at refuelling interval of:

1 hr

2hr

* NOTE: Figures are for heat from the appliance 

only

. There will typically be additional, often substantial, heat gains 

from   the  masonry  of  the   fireplace  and  chimney,   and  consequent  higher  total  efficiency.  Total   performance  for   a 
particular building can be calculated by the method of EN13384

Manufactured by: Esse Engineering Ltd

Long Ing, Barnoldswick, Lancashire 

BB18 6BN,

 England

www.esse.com

This document, when completed by the installer, constitutes a 'Hearth Notice' for purposes of the England and Wales 
Building Regulations 2000, (App. Doc. J4). It must be left with the householder and placed where it can easily be found.

APPLIANCE SERIAL NUMBER:

INSTALLED AT LOCATION:

BY:

EMERGENCY TELEPHONE:

SIGNED:                                                       DATE:

Who certifies that this installation is safe, has been demonstrated to the householder, 

conforms with current building regulations and with these instructions

Flue Draught 

measured on 

commissioning:

Fuel used on 

commissioning

 

TO FIND A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY SWEEP, CONTACT:

UK: 

The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55 7AS Tel:0845-601-4406 

www.solidfuel.co.uk

RoI:

 Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959 

www.fireplace.ie

1

Pa

Отзывы: