background image

 

 

firewall 

FLUELESS CAT GAS FIRED HEATER 

Model: 39” Original 

Fully Remote Control 

USER INSTRUCTIONS 

(TO BE LEFT WITH THE CUSTOMER) 

For use in the UK & Ireland on Natural gas at a supply pressure of 20 mbar 

or Butane/Propane at a supply pressure of 28 mbar/37 mbar 

ESSE Engineering, Long Ing, Barnoldswick, Lancashire BB18 6BN 

Tel: 01282 813235 Fax: 01282 816876 

Email: [email protected] Website: http://www.esse.com 

GB  IE 

Содержание Firewall 39" Original

Страница 1: ...EFT WITH THE CUSTOMER For use in the UK Ireland on Natural gas at a supply pressure of 20 mbar or Butane Propane at a supply pressure of 28 mbar 37 mbar ESSE Engineering Long Ing Barnoldswick Lancashi...

Страница 2: ...ge 7 Important Notes Page 2 Burner Arrangement Page 7 Clearances Page 3 Control for the Heater Page 7 Batteries in Handset Page 4 Combustion Monitoring System Page 8 Handset Operation Page 5 Cleaning...

Страница 3: ...and must be carried out by a qualified per son Under no circumstances should the appliance be operated without the glass frame attached or the glass damaged All surfaces except the controls are consi...

Страница 4: ...o leave deposits on colder and damp walls when heated If the interior climate is bad this phenomenon may also occur above radiators and lighting fixtures and at ventilation grilles although to a lesse...

Страница 5: ...dset Fig 2d Battery removed from Handset Place the Handset on the reverse side and locate the battery compartment push the panel down to release Locate the Zinc Chloride Battery 9V in battery compartm...

Страница 6: ...ess SMALL FLAME button to decrease the flame Fig 3a TIME DISPLAY SETTING THE TIME The Time display will flash after either A Installing the battery or B Simultaneously pressing the LARGE and SMALL fla...

Страница 7: ...ep is short and the second beep is long After the second beep release the reset button Within the subsequent 20 seconds press the small flame button on the handset until you hear two additional short...

Страница 8: ...UST NOT be installed in a bedroom bathroom or any sleeping area Additionally for L P G the heater must not be used in cellars or basements 8 BURNER ARRANGEMENT The burner should only be used with verm...

Страница 9: ...ing use for no apparent reason then several reasons may be suspected If a door or window has been opened creating a draught then pilot disturbance could be the problem and removal of the draught shoul...

Страница 10: ...ESSE Engineering Long Ing Barnoldswick Lancashire BB18 6BN Tel 01282 813235 Fax 01282 816876 Email enquiries esse com Website http www esse com 05 12 PP INSTR FW 39 u...