Page 7
TECHNICAL INFORMATION
Cut your logs to the approximate size shown in Figure 6 to minimise the need
for refuelling.
Figure 6 Approximate Size of Logs
Technical Information
Nominal heat output
5.0kW
Minimum chimney
draught
12Pa
Combustion air
requirements
29m
3
/h
Mean flue
gas temperature
170
o
C
Weight of appliance
Bakeheart:
Warmheart:
192 kg
154 kg
Flue gas mass flow
10g/s
Hot water
2.8kW Heat to room
780m
2
> 100 m
2
Average oven temp
180°C Max oven temp
240°C