Page 20
990EL-I02-121016
Pot Detection:
If cookware is not detected, the ‘suspended pot’ is shown on the
Induction status display. If no cookware is recognised, the
induction zone will switch off automatically after 10 minutes.
Residual Heat Display:
After turning off the induction unit, the residual heat on the
cooking element is displayed as an H, this will remain as long as the
temperature is over approximately 60°C
Over-Temperature Protection:
Temperature sensors monitor the temperature beneath and inside
the induction zone. When excessive temperature is monitored in
the ECU, the induction zone will reduce power in 4 steps until the
temperature reduces to safe levels. When excessive temperature is
monitored at the hob, the induction zone will stop operation
automatically.
The minimum pan size for the induction zone is Ø145mm.
This Induction unit has a built in cooling fan which comes on when
the induction unit is switched on and the temperature exceeds 40°C
and will go off once the temperature drops below 30°C, regardless
of whether the induction is turned on or off. When the unit is set to
slumber mode, this should only take a matter of minutes however
when the cooker is at the higher end of the temperature scale (i.e.
cooking) this can take longer to turn off.