Page 9
39P-I01-160617
VENTILATION
A minimum of 100cm² purposely provided ventilation is required for this heater. An
openable window of equivalent is also required. The requirements of any other flued
appliance operating in the same room or space must be taken into consideration when
assessing ventilation.
Any ventilation fitted must comply with BS 5871 and BS 5440 part 2. Ventilation fitted
under, or within immediate vicinity of the heater must not be used as it may adversely
affect performance of the ODS system.
For Republic of Ireland, see relevant rules in force and I.S.813.
SECURING THE HEATER TO THE WALL
Select a suitable site for the heater.
Remove the glass frame securing nuts and remove the glass frame complete, by tilting
the base of the frame out and lifting upwards. Store the glass frame and nuts
somewhere safe.
Remove the wall plate from the heater body (4 x M5 nuts) (Fig.2).