Alarm system for elevators 

compliant with the European Standard  

EN 81-28:2018

 

 
 
 

 

 
 
 

HELPY CONTROLLER

  

 
 
 
 
 
 
 

QUICK GUIDE

 

 
 
 
 
 

Содержание HELPY

Страница 1: ...05 04 2019 Alarm system for elevators compliant with the European Standard EN 81 28 2018 HELPY CONTROLLER QUICK GUIDE...

Страница 2: ...levator controller A Connectors for optional PSTN line board B LEDs C Reset pushbutton D Micro USB A B port for PC connection E Serial port for PC connection F RJ45 connector for GSM Satellite G Termi...

Страница 3: ...ed to a block to the block 12 V Out or to an external reference 2 allows to connect voltage free contact NO or NC or powered contacts Optional PSTN line board LTI PSTN line or universal GSM gateway in...

Страница 4: ...e connector take care to only rotate the metal ferrule to fix the antenna do not rotate the antenna on itself Push the SIM Card housing cover as indicated by the arrow OPEN until it unlocks and lift i...

Страница 5: ...y Controller by means of the supplied cable PSTN line or universal GSM gateway Insert the optional PSTN line board in the dedicated connectors A in the picture at page 2 Connect the ground terminal in...

Страница 6: ...sive speaker unit can be connected to each 2W speaker unit and allows to double it The passive speaker unit can be installed at max 6 m distance from 2W speaker unit by using a shielded cable Each 2W...

Страница 7: ...pply input 12 Vdc Negative AR Received alarm indicator light light positive pole AI Given alarm indicator light light positive pole AR Received alarm indicator light light negative pole AI Given alarm...

Страница 8: ...ing microphone of passive speaker unit or single microphone Negative H Microphone DIP switch The DIP switch allows to assign an ID 01 16 to each 2W speaker unit connected to the bus Note it is possibl...

Страница 9: ...ENCY CALL BUTTONS It is possible to connect external pushbuttons voltage free contact pushbuttons or powered pushbuttons to 2W speaker units without built in pushbutton Connect following one of the di...

Страница 10: ...to indicate the beginning of the alarm procedure The RECEIVED ALARM INDICATOR LIGHT green switches on when the alarm call is answered Some 2W speaker unit models come with built in indicator lights I...

Страница 11: ...ED TO FILTER CONTACT TERMINAL BLOCKS 12 V Out IN1 IN1 12 V Out external reference IN1 external reference Note if a 2W speaker unit is installed in the cabin it is possible to use the terminal block s...

Страница 12: ...Page 12 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAM WITH 2W SPEAKER UNITS IN THE CAR AND IN THE PIT AND PASSIVE SPEAKER UNIT ON CAR TOP...

Страница 13: ...WIRING DIAGRAMS Page 13 WIRING DIAGRAM WITH LANDING FLOORS...

Страница 14: ...nd dial Make an external call to check the GSM satellite module is properly working dial and after the Correct message digit the telephone number to make a test call or Make an external call to check...

Страница 15: ...ult Press to end the alarm 2nd mode automatic reset Hang up or press to end the alarm 3nd mode automatic reset with local acknowledgement Hang up to end the call Press the reset pushbutton or close th...

Страница 16: ...t page 2 Pressing shortly Allows to interrupt an alarm call By pressing shortly you get the same result as lifting the handset of the local telephone and entering Password Pressing longer 10 seconds A...

Страница 17: ...fault EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD factory default TELEPHONE NUMBERS INST the programming of the telephone number automatically activates the alarm call position from 01 to 1...

Страница 18: ...AY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY TIME INST hhmm from 0000 to 2359 RECORD MESSAGES INST identification message max 25s record hang up courtesy message max 25 s LISTEN TO MESSAGES INST OPER...

Страница 19: ...28 2004 Make a test call manually PROTOCOLS IDENTIFICATION CODE INST Esse ti identification code P100 SPEAKER UNITS VOLUME INST OPER speaker unit ID from 01 to 16 loudspeaker from 1 to 9 factory defau...

Страница 20: ...ST speaker unit ID from 01 to 16 AL1 0 normally closed 1 normally open AUX 0 alarm NC 1 alarm NO 2 auxiliary NC 3 auxiliary NO 4 filter NC 5 filter NO NO EXTERNAL POWER SUPPLY ALARM INST disabled alar...

Страница 21: ...messages from 02 to 59 00 no courtesy message 01 one courtesy message for each call COMMUNICA TION ACTIVATED MESSAGE SETTING INST disabled message enabled message HANDSFREE CONNECTION MODE DURING AN...

Страница 22: ...NO 01 GB AE 02 DE LB LU 03 FR GP GF 04 PL 05 PT 06 RU BY 07 ES AD CY 08 BG BR KY DK ID IR IS KW MO MW MX PY UY VE YE ZM FO LR 10 HR 11 GR EE FI 12 NL AW VU 13 SI 14 HU 15 IL 16 AT 17 AU IE 18 CH 19 CN...

Страница 23: ...rom 0 to 9 1 master 0 function disabled DTMF GENERATOR SETTING INST DTMF generated by GSM network DTMF generated by Helpy Controller DTMF duration X 50ms from 1 to 9 factory default 2 LISTEN TO THE GS...

Страница 24: ...INST LISTEN TO THE BATTERY LEVEL INST expressed in mV LISTEN TO THE EXTERNAL POWER SUPPLY LEVEL INST expressed in mV TEST OF ALARMS INST emergency call button battery alarm periodic automatic test ca...

Страница 25: ...puter by using the USB serial proprietary cable and the dedicated e stant software e stant software also allows to update the firmware of the Helpy Controller customize the messages of the Helpy Contr...

Страница 26: ...ich allows access to programming and the programming codes to be performed The message format must be as follows Et he xxx c c c c Where Et he is the start of the programming string xxx is the passwor...

Страница 27: ...G CONVERSATION WITH THE SPEAKER UNITS CABIN SPEAKER UNIT ID 01 SPEAKER UNIT ID 02 SPEAKER UNIT ID 03 SPEAKER UNIT ID XX 04 16 DEACTIVATE ALL EXTERNAL CALLS TELEPHONE NUMBER Use remotely with Helpy Con...

Страница 28: ...ng All of the programming and functions below can now be performed USE REMOTELY WITH HELPY CONTROLLER AT REST PROGRAMMING CONVERSATION WITH THE SPEAKER UNITS CABIN SPEAKER UNIT ID 01 SPEAKER UNIT ID 0...

Страница 29: ...Voice connection Battery disconnected or low battery max 1 hour operation in idle state 2W speaker unit connection error or bus problem Absence of telephone line Button failure LED signalling data tr...

Страница 30: ...nal level Medium signal level Good signal level High signal level Note the green LED on GSM satellite turns on during a call or when the local telephone is used LED signalling alarm periodical test ca...

Страница 31: ...the battery has low capacity charge The external power supply is connected and the battery is either disconnected or dead The external power supply is disconnected and the battery guarantees more tha...

Страница 32: ...ems Call in progress Given alarm indicator light yellow Alarm Received alarm indicator light green Voice connection Missed test call notification The Given alarm indicator light and the Received alarm...

Страница 33: ...ti S r l declares that the equipment type Helpy Controller is in compliance with Directives 2014 30 EU 2014 33 EU 2014 35 EU The full text of the EU declaration of conformity is available from the fo...

Страница 34: ...Page 34 NOTE NOTE...

Страница 35: ...NOTE Page 35...

Страница 36: ...Esse ti S r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it support esse ti it...