INSTALLING
Page 3
LED signalling alarm / periodical test call (yellow)
LED signalling GSM signal strength (green)
LED signalling GSM status (red)
LED signalling power supply status (blue)
Terminal blocks
N.
NAME
DESCRIPTION
01
+
POWER SUPPLY INPUT (11-14VDC)
(1)
02
–
03
AIP
GIVEN ALARM INDICATOR LIGHT (output: 12VDC)
04
ARP
RECEIVED ALARM INDICATOR LIGHT (output: 12VDC)
05
+12
12VDC OUTPUT (max. 100mA)
06
C
COMMON TERMINAL FOR INPUT ALC
(2)
07
–
NEGATIVE POLE
08
ALC
ALARM INPUT FOR THE ELEVATOR CAR
(3)
09
ALY
ALARM INPUT FOR THE PIT
(4)
10
IN1
FILTER INPUT
11
ALT2
OUTPUT FOR CONNECTING THE LOUDSPEAKER OF A PASSIVE SPEAKER
UNIT
12
MIC2
INPUT FOR CONNECTING THE MICROPHONE OF A PASSIVE SPEAKER
UNIT OR A SINGLE MICROPHONE
13
MIC3
INPUT FOR CONNECTING THE MICROPHONE OF A PASSIVE SPEAKER
UNIT OR A SINGLE MICROPHONE
14
–
NEGATIVE POLE
15
TEL
LOCAL TELEPHONE
16
RL1
RELAY
(5)
17
RL1
RELAY
(5)
18
VVX
OUTPUT FOR CONNECTING AN ADDITIONAL ACTIVE SPEAKER UNIT
19
VVY
OUTPUT FOR CONNECTING THE PIT ACTIVE SPEAKER UNIT
20
ALZ
ADDITIONAL ALARM INPUT
(4)
OR AUXILIARY INPUT
(5)
21
AIN
GIVEN ALARM INDICATOR LIGHT (output: 0VDC)
22
ARN
RECEIVED ALARM INDICATOR LIGHT (output: 0VDC)
23
C-L
CAN-BUS
24
C-H
CAN-BUS
25
TX
RS-232
26
RX
RS-232
27
–
NEGATIVE POLE
28
C1
COMMON TERMINAL FOR INPUT IN1
(2)
(1)
: before using this input disconnect the internal power-supply cable from the A
connector in the picture at page 2
(2)
: can be connected to a block
–
, to the block
+12
or to an external reference
(3)
: allows to connect voltage free contact pushbuttons (NO or NC) or powered
pushbuttons
(4)
: allows to connect voltage free contact pushbuttons (NO)
(5)
: free contact NO