PROGRAMMING
Page 23
ADVANCED PROGRAMMING
NUMBER OF
CALLS TO THE
SAME NUMBER
FOR EACH CYCLE
(INST)
(calls, from
1
to 9)
CALL CYCLES FOR
EMERGENCY CALL
ALARMS
(INST)
(cycles, from 1 to 9;
0
=unlimited)
CALL CYCLES FOR
TECHNOLOGICAL
ALARMS AND
TEST CALLS
(INST)
(cycles, from 1 to 9; 0=10 cycles;
factory default
3
)
WAITING TIME
BETWEEN
TECHNOLOGICAL
OR TEST CALLS
(INST)
(minutes, from 01 to 99;
00=30 seconds, factory default
02
)
AUTOMATIC
ANSWER
(INST)
(ring number, from 1 to 9;
0=disabled; factory default
2
)
OPERATION
MODE AFTER
AUTOMATIC
ANSWER
(INST)
programming mode
direct connection with the car
CONNECTION
DURATION AFTER
AUTOMATIC
RESPONSE
(INST)
(minutes, from
1
to 9)
CLI CALL
DURATION
(CLI)
(seconds, from 00
to 99; factory default
10
)
DTMF
GENERATOR
(INST)
(from 1
to 9; factory default
2
;
DTMF duration=X*50 ms)
MULTI-LINK
FUNCTION
(INST)
(from
0
to 9; 1=master, 0=function disabled)
RELAY
INTERMITTENCE
(INST)
steady-state
intermittent (500 ms ON / 500 ms OFF)