MANUAL FOR INSTALLATION AND MAINTENANCE 

 

Espresso Coffee Machines:  

H-Series 

Energy, Galaxy, Eccobar, Torino, etc

 

 

 

 

       

automation 4 espresso 

GRUPO 1000  BARCELONA, S.L.U. 
C/ Joan Torruella i Urpina 37, Nave 5  
08758 Cervelló (Barcelona) - Spain 

[email protected]

 

Tel. 616 28 77 21 

Linea Energy 

Linea Torino 

Linea Galaxy 

Linea Venezia 

Linea Eccobar 

Содержание eccobar series

Страница 1: ...es H Series Energy Galaxy Eccobar Torino etc automation 4 espresso GRUPO 1000 BARCELONA S L U C Joan Torruella i Urpina 37 Nave 5 08758 Cervelló Barcelona Spain info grupo1000 com Tel 616 28 77 21 Linea Energy Linea Torino Linea Galaxy Linea Venezia Linea Eccobar ...

Страница 2: ... 4 Hot water spigot 3 5 Steam wand 3 6 Cleaning procedures 3 7 Water softener not included 3 8 Alarm signs 4 INSTRUCTIONS FOR THE TECHNICIAN 4 1 Description of the internal components 4 2 Positioning of the machine 4 3 Connection to water net 4 4 Connection to electrical net 4 5 Security valve 4 6 Vacuum valve 4 7 Expansion valve 4 8 Water level inside the boiler 4 9 Internal insulation 5 PRODUCT ...

Страница 3: ...ized to do the job by the manufacturer e The manufacturer will not accept any responsibility for personal and material damages or losses caused by an incorrect installation of the machine f Security of the machine can be only proven if it has been properly connected to a ground point always done accordingly with effect local rules see paragraph 4 3 g It is very important that these basic security ...

Страница 4: ...reme temperatures It can work on the exterior terraces etc but the maximum air temperature should not exceed the 50ºC 122ºF and the minimum should not be lower than 0ºC 32ºF Don t let temperatures lower than 0ºC 32ºF be in touch with the machine without emptying first the boiler and pipes of water Don t let any person use the machine if they have not read carefully the user s manual before Don t l...

Страница 5: ...d avoid any danger v Unplug the machine from the electrical net when the device is not going to be used for a long perod of time usually more than 3 days To make sure the machine is working properly it is totally indispensable to fulfill these instructions provided by the manufacturer In particular it is important to check all what is related with security It is important to not use hands or other...

Страница 6: ...the machine 1 group 2 groups or 3 groups Touchpads Membranes 1 2 or 3 with 5 programable boutons Capacity of the boiler 3L 6L 12 L or 18L Power 1 800W 2 600W or 5 000W Pressure stat 20 A Boiler pressure 100 kPa 1 Bar Pump pressure 900 kPa 9 Bar Net water minimum pressure 300 kPa 3 Bar Steam wands 1 or 2 Water spigots 1 Water net connection Thread 3 8 Filter holders handles 1 for 1 Coffee and 1 2 o...

Страница 7: ...team faucet tap 2 Hot water faucet tap 3 Net Pump pressure gauge 4 Touchpad for coffee dosage 5 Burn protector 6 Steam wand 7 Service tray 8 Insulating legs 9 Coffee filter holder 10 Group head for coffee 11 Hot water spigot 12 Main switch ...

Страница 8: ...pped with a double probe system One probe is to protect the heating element Security probe and the other probe is to control the water level inside the boiler Level probe First probe will allow the machine to heat the water when it arrives to that minimum level inside the boiler and the second probe will limit the filling of the boiler avoiding the boiler from exceeding its water level Otherwise t...

Страница 9: ...lways vary but a lack of water coming from the net as a consequence of a wrong use of the C button could overheat and damage the pump And on the contrary a never ending leak of water coming out from the group heads with no control of the user could cause severe damages and losses to the local either is a possible flood or sparks as a result of possible contact between water and electricity So just...

Страница 10: ...dy to start next day 3 7 Water softener not included Ask your technician about water softeners It is always convenient to use a water softener to prevent future problems Scale lime is always the worst enemy of the machines The softener extracts the scale from inlet water avoiding the creation of lime deposits and encrustations i e many problems in the future There is different types of softeners I...

Страница 11: ...able way 4 4 Connection to electrical net Again as mentioned in paragraph 3 2 the technician must install the machine to the electrical power supply before the machine is turned on In case the machine comes without plug usually it comes without it the technician will need to install a plug or a multiple connector strip on the electrical cable Moreover it is important for the technician to verify t...

Страница 12: ... to provide the user enough steam to froth the milk etc 4 9 Internal insulation The machine is equipped with double insulation on its internal wiring to provide security to technicians when operating or servicing the machine as well as for end users etc 5 PRODUCT CERTIFICATIONS Having gone through all the necessary tests in the Electrical Test Lab SGS TECNOS S A U based In Madrid Spain we certify ...