<program stage 0>
s111111 (enable all shutter outputs for this stage)
f111111 (enable all focus outputs for this stage)
d100 200 300 400 500 600 (assigns each output delay to 100 200 300 400 500 600 millisconds)<br>
<program subsequent stages>
P (add stage)
j1 (select stage 1)
s111111 (enable all shutter outputs for this stage)
f111111 (enable all focus outputs for this stage)
d0 0 0 0 0 0 (assigns each output delay to 0 millisconds)<br>
<fire shutters>
j0 (selects sequence point 0)
F1 (focus camera)
<wait camera response time value> (allow camera to respond to half button press)
S (release shutter)
F0 (release focus)
Complete commands list
Tip:
All commands that do not return a data string will return "tenFour", with the exception of the
fire the shutters command. It is advised to wait for the TriggerBox to print "tenFour" before issuing
another command.
General Commands:
Command
Description
S
Fire the shutters. If the box is in Sequencer Mode, it will move to
the next available stage.
F1
/
F0
Assert or de-assert the focus outputs, according to the current
focus enable settings.
bxxxx
Set bulb time (how long the shutter control line is asserted in
milliseconds).
B
Print "BulbTime:[xxxx].
d8 23 456 99 32 1
Set the current sequencer stage delay values. (also prints "updating
stage delay tables").
D
Print the current sequencer stage delay array "Delays:[12 23 34 45
56 67 ]".