The control wire must be passed through the
protective wire aperture in the unit casing and
plugged into the controller socket.
The power supply must go through the
protective wire aperture in the unit casing and
be connected securely to the terminals in the
control box. There is an alternate access
grommet in the casing near to the drain-off point.
In section 13 you will find wiring diagrams for the. Please refer to these
diagrams when introducing power or other wiring into the unit. You
should also use these diagrams to check the installation through before
starting the unit for the first time.
If the Building Regulations in your area require a 7-day programmer,
please note that the most efficient way of running an ASHP heating
system is to set the programmer to ALWAYS ON. A programmerthat
meet current building regulations may be used but it is
very
IMPORTANT
that any signal going back to the heat pump from the heating system
thermostat and/or programmer must be
VOLT FREE !
The heating
system thermostat/ programmer controller is wired to terminals 45&46
inside the heat pump (these connections are not polarized) If you do not
use a
volt free
programmer you WILL damage the ASHP unit.
Mains power
Connector Block
Controller
Connector
Содержание Varimax 20 ASHP
Страница 1: ...1 of 41 V 1 0 www esavep com PASRW060 D BP ESP VARIMAX 20 ASHP Installation and Operation Manual...
Страница 34: ...34 of 41 V 1 0 www esavep com PASRW060 D BP 13 0 Wiring Diagram For zero volt connection from Controller...
Страница 38: ...38 of 41 V 1 0 www esavep com PASRW060 D BP 17 0 Performance Frequency HZ Frequency HZ Frequency HZ...
Страница 39: ...39 of 41 V 1 0 www esavep com PASRW060 D BP Frequency HZ Frequency HZ Frequency HZ...