SENSOR SETUP MENU
SENSOR RECORD TIME:
Recording duration once sensor
Being triggered.
Selects record time from 0 ~180 seconds.
ALARM OUT TIME:
It controls how long ( in second)
the alarm sounds after being triggered.
Selects alarm ON time from 0 ~ 30 or
continuous.
SENSOR SET UP
Use the
ϰ
and
ϧ
buttons to select
channels 1 ~ 4.
Use the
button to select options
(Normal Open/Close)
Press the
button to exit
In normal open mode
the cable line Connected between
the sensor and the unit is cut off by
an intruder, the unit starts recording
.
In normal close mode,
the cable line connected between
the sensor and the Unit is cut off by
an intruder , the unit stops recording.
SENSOR SETUP
SENSOR RECORD TIME 15
ALARM ON TIME 20
SENSOR SET UP
MOTION SETUP
PRESS (<,>) THEN (SELECT)
PRESS (MENU) TO EXIT
SENSOR SETUP
CHANNEL-1 NOT INSTALL
CHANNEL-2 TYPE:NORMAL-OPEN
CHANNEL-3 TYPE:NORMAL-CLOSE
CHANNEL-4 TYPE:NORMAL-OPEN
PRESS (<,>) THEN (SELECT)
PRESS (MENU) TO EXIT