10. Safety Notes:
DANGER for children! Keep your children away from small parts which may
present a choking hazard (standpipe and sprinkler) and the packing material
fern. There is danger of suffocation!
WARNING of trip hazards! Please lay the connection cable so that it won’t
constitute a tripping hazard!
CAUTION material damages! If you set up the solar module without any
module mounting you will have to pay attention to an adequate stability. The
solar module may be damaged due to toggling or impact by foreign bodies.
Disposal:
Dear customer,
please cooperate in avoiding waste. When you intend to dis-
pose of the product in future, please consider that it contains
valuable raw materials suited for recycling.
Therefore, do not dispose it of with domestic waste but bring
it to a collection point for the recycling of waste electrical and
electronic equipment.
Thank you very much for your cooperation!
Copyright, esotec GmbH
6. Dry run protection
The pump is equipped as standard with a dry run
protection. Two sensor points are provided on the
side of the housing for this. The pump works if these
points are under water. If a point projects out of the
water, the pump does not work.
7. Malfunctions
Solar pump does not work:
- Accumulator box switched-on?
- Pump not under water (dry run protection, see manual of the pump)
- After a long standstill in winter, it is required to charge the accumulator via
the solar module. The accumulator should be exchanged every 2 - 3 years.
- Accumulator is discharged. Wait for sunshine and, if required, switch-off the
accumulator box for one day and have it recharged.
- Pump clogged. Cleaning according to the manual of the pump!
- Check plug connection at the cable.
8. Storage during the winter
In case of sub-zero temperatures, i.e. during the winter, the pump and the accumu-
lator box have to be stored at a warm place. Before storing it, clean the pump with
lukewarm water as described in the manual of the pump. Switch-off the accumulator
box (position “OFF”, for further notes, see manual of the accumulator box).
9. Technical Data
Solar pump system:
Fountain 8/300
- System voltage:
6 - 9 VDC
Solar module
- Cell type:
polycrystalline
- Number of cells:
16 pieces
- Nominal power:
8 Wp
- Nominal voltage:
8,64 V
- Nominal current:
926 mA
- Protection class:
IP 65
- Temperature range:
-30°C to +75°C
Water pump:
- Operating voltage:
6 to 9 V DC
- Power consumption (6V/ 9 V): approx. 1,2 W/ 2,8 W
- Max. lift (6V/ 9 V):
approx. 0,5 m/ 1,1 m
- Flow rate (6V/ 9 V):
approx. 220 l/h/ 300 l/h
- Protection class:
IP 68
- Operating temperature range: +4 to +40°C
- Dry running:
dry run protection
Accumulator box:
- Max. pump runtime with fully
charged accumulator:
approx. 4 h
- Accumulator voltage:
6 V
- Accumulator capacity:
3,2 Ah
- Overcharge protection:
approx. 6,7 V
- Depth discharge protection:
approx. 5,6 V
- Voltage threshold for restart:
approx. 6,2 V
- Output voltage: :
6 - 9 V DC (adjustable)
- Max. load current (output):
3 W
- Max. connectable module capacity (input): 8 Wp
- Protection class:
IP 44
- Protection grade:
III
Sensorpoints
Customer support:
If you have problems or questions regarding this product, simply contact us!
Monday to Friday 9 am to 12 noon and 1 pm to 4 pm.
By phone: +49 9605-92206-0
By e-mail for ordering spare parts: [email protected]
By e-mail for questions about the product: [email protected]
Product: Manufacturer Item No.: 101923
Battery take-back
- Batteries must not be discarded into domestic waste.
- The consumer is legally required to return batteries after
use, e.g. to public collecting centers or to battery distribu-
tors.
- Contaminant-containing batteries are labeled with the sign
“crossed-out trashcan“ and one of the chemical symbols.
Used batteries should be disposed environmentally friendly
and should not be discarded into domestic waste. Your
dealer is legally required to take back old batteries.
Pb