Note:

The  outputs  1  through  3  are  connected  by  means  of  system  plugs.

Corresponding manifolds are available as accessories. The protective caps
have to be tightened firmly. Not used outputs have to be closed by means of
the corresponding protective caps. The plugs are protected against reverse
polarity.  Please do not apply force when inserting the plugs!

5. LED Displays

- „SYSTEM“

This display is illuminated in green if the
accumulator is ready for operation. Is illu-
minated in red if the accumulator is
exhaustively/deeply discharged and the
outputs are switched off. 

- „CHARGING“ 

This display is illuminated in yellow if the integrated accumulator is char-
ged. This LED flashes if the accumulator is fully charged and is on trickle
charging.

- „OUTPUT 1 - 4“ and „Timer“ 

This display is illuminated in green if the output is activated. In case of a
short circuit, the corresponding green LED will flash and the output will be
switched off until the short circuit is eliminated.   

6. Exchange of the accumulator

We recommend an exchange of the accumulator approx. every 2 to 3 years. A
new identical in construction accumulator is available from the manufacturer or
dealer. 

Proceed as follows if you want to exchange the accumulator:

1.  Set the main switch 

(SYSTEM ON/OFF)

on the back side of the accumula-

tor box in into the position „OFF“ and unplug all connectors/plugs. 

2.  Turn  the  accumulator  station  upside  down  and  loosen  the  bottom  four

screws. 

3.  Then turn the accumulator box around again and carefully remove the lid. 
4.  Loosen the + pole and - pole connection on the accumulator using suitable

tools. 

5.  Remove the accumulator from the box and insert the new identical in con-

struction accumulator.

6.  Reattach the cable lugs on the accumulator using suitable tools. In doing so,

please pay attention to the cable color:  positive pole (brown) and negative
pole (blue).

7.  Close the box in reverse order.

Note:

Please  only  use  an  identical  in  construction  accumulator  with  identical

voltage and capacity. 

Note:

The old accumulator has to be disposed of in an environmentally sound

way.  For  this  purpose,  please  contact  you  local  authorities,  public  collection
points or your dealer. 

7. Overwintering

Fully charge the accumulator in the accumulator box. For this purpose, use a
sunny day and switch off the switch „SYSTEM ON/OFF“. Store the accumulator
box over the winter only in a fully charged status in a frost-free room. At sunny
days, you may occasionally connect the accumulator box to the solar module
for charging purposes. This will ensure an as long as possible service life of the
accumulator.  

8. Troubleshooting

LED is not illuminated green in spite of solar radiation but the yellow LED
is illuminated.

1.  The accumulator has not yet been charged sufficiently and the restart thres-

hold is not reached. The charging process may take several hours in case
of insufficient solar radiation. 

2.  Accumulator is exhausted! The accumulator should be exchanged approx.

every 2 years. Please see item 6 of this instruction.

The  LED  is  not  illuminated  green  in  spite  of  solar  radiation  when  swit-
ching-off and on again of the switch “System ON/OFF”, the pump starts to
work and the green LED is illuminated 

1. The accumulator has not yet reached its restart threshold. The electronics is

reset after the deactivation and activation of the system and the connected
consumers are supplied with energy without waiting for the restart threshold.
This is a normal process and does not indicate any defect.

A green LED above an output flashes.

1.  There  is  a  short  circuit  on  the  output.  Please  check  the  connected  device

and all plug-in connections (particularly those of the pumps and the LED illu-
mination) for tightness.

2.  Check the cables for damages of animal bites. 

The yellow LED „CHARGING“ is illuminated, nothing else works.

1.  Has the switch „SYSTEM ON/OFF“ been switched on (position ON)?
2.  If  yes,  then  please  switch  off  the  switch  „SYSTEM  ON/OFF“  for  approx.  1

minute and switch it on again. 

9. Technical data: 

Max. connectable module power (input): 

50 Wp

Protection class: 

IP 44

Accumulator voltage: 

12 V

Accumulator capacity:

24 Ah

Overcharge protection:

approx. 13,8 V

Deep discharge protection:

approx. 11,8 V

Voltage threshold for restart: 

approx. 12,65 V

Outputs:
- Output 1: 

DC 6 V/ 1 A

- Output 2: 

DC 12 V/ 1 A

- Output 3: 

DC 12 - 18 V/ 1 A

- Output 4: 

DC 12 V/ 4 A

WARNING of trip hazard!

Please lay the connection cable so that it does not

constitute a trip hazard!

Disposal:

Dear customer,
please  cooperate  in  avoiding  waste.  When  you  intend  to  dispose  of  the  product  in
future, please consider that it contains valuable raw materials suited for recycling.
Therefore, do not dispose it of with domestic waste but bring it to a collection point for
the recycling of waste electrical and electronic equipment. 
Thank you very much for your cooperation!

Manufacturer:

esotec GmbH  -  

Gewerbegebiet Weberschlag 9  -  D-92729 Weiherhammer

Tel.-Nr: +49 9605-92206-0  -  Fax.-Nr: +49 9605-92206-10
Internet: www.esotec.de

Copyright! esotec GmbH

Battery take-back

-  Batteries must not be discarded into domestic waste.
-  The  consumer  is  legally  required  to  return  batteries  after

use,  e.g.  to  public  collecting  centers  or  to  battery  distribu-
tors. 

-  Contaminant-containing batteries are labeled with the sign

“crossed-out  trashcan“  and  one  of  the  chemical  symbols.
Used batteries should be disposed environmentally friendly
and  should  not  be  discarded  into  domestic  waste.  Your
dealer is legally required to take back old batteries.

Pb