Fill tank with approximately 6” of liquid. NEVER OPERATE UNIT
WITHOUT LIQUID IN TANK.
The unit must be electrically grounded. Connect to a three-way
grounded outlet. If you have a 2-wire service, an adapter with external
ground wire is necessary. Connect the green grounding wire of the
adapter to the screw which holds the electric outlet plate cover to the
socket.
DO NOT OPERATE UNIT WITHOUT PROPER GROUNDING
.
Operation
The basic principle of operation is the enhancement and
acceleration of the chemical cleaning through cavitation created by
ultrasonic waves.
Parts to be cleaned are placed in rack (basket) and rack is
positioned into the ultrasonic tank. Never place parts directly on bottom
of tank (tank could eventually be perforated).
1.
Heater – If unit is supplied with heat (optional), the heater switch,
located on lower left of unit, will activate heater when turned ON (Red
indicator light is ON). The heater is thermostatically controlled to keep
liquid in tank at approximately 120ºF
Timer – Turn timer knob clockwise to desired time to start ultrasonic
action. When set time expires, the ultrasonic action is terminated. Green
indicator light is ON during cleaning
Never try to remove tank from cabinet. The tank is sealed into the
cabinet in order to prevent any liquid from penetrating inside and
damaging the electronics.
Maintenance
Periodically, the ultrasonic cleaning solution in the tank must be
changed:
-Unplug unit from 115VAC outlet.
-Drain liquid into a container or sink by opening the valve at the rear of
unit.
-After tank is empty, flush out tank and drain it.
-Wipe tank clean and dry.
-Close drain valve and add fresh solution.