Switch on the PC and the monitor.
2
Table Power
Switch the table on using the
Main Power Switch
.
Note: After power off, wait minimum 5 sec. before the system is switched on
again.
3
Xx-Guide
Use the mouse, double-click the icon for
XE-Guide
.
Check that no error message indicates faulty conditions.
4
Safety System
Reset the
Safety System
by pressing the
Stop
pushbutton.
5
Servo Power
Press the
Servo On
pushbutton.
The
Warning Lamp
on top of the Y carriage should be constantly lit. Any
malfuction of the lamp must be corrected as soon as possible since this is a
safety feature.
6
Table Zero Sequence
Press
Start
pushbutton to complete the
Table Zero Sequence
.
The machine will move to the
Selected Reference Point
.
7
Spindle Warm-up (milling toolhead only)
Run Warm-up sequence by pressing this button in iPC. The spindle warning
lamp (red) should flash shortly and then light constantly. This indicates that
the spindle rotates. Any malfunction of the lamp must be corrected as soon as
possible since the lamp is a safety feature.
8
The table is now ready for operation.
4.5.2. Reset Safety System
Press
Pause
to
Reset Safety System
.
12