MAINTENANCE ITEM
Every 8 hours (daily)
Every 20 hours or seasonally
Yearly
Clean Engine and Check Bolts and Nut
X
Air Filter
Check
X
(See Air Filter section)
Clean *
X
Replace
X
X
Spark Plug (Gap 0.028”)
Check/Adjust
X
(See Spark Plug section)
Replace
X
SERVICE, TROUBLESHOOTING, AND REPAIR
Service Information
At Ardisam, we build quality and durability into the design
of our products; but no amount of careful design by us, and
careful maintenance by you, can guarantee a repair-free life
for your unit. Most repairs will be minor, and easily fixed by
following the suggestions in the troubleshooting guide in this
section.
The guide will help you pinpoint the causes of common
problems and identify remedies.
For more complicated repairs, you may want to rely on your
retailer or an authorized repair center (contact your retailer for
a list of authorized mechanics in your area). A parts breakdown
can be found on our website, www.geteskimo.com.
We will always be glad to answer any questions you have, or
help you find suitable assistance. To order parts or inquire
about warranty, call or write us at the address found on the
next page, under the section “ordering repair parts”.
Ice Point Replacement (See Figure 1)
1. Remove blade protector and both blades.
2. Remove nut and retaining bolt from point.
3. Using a locking pliers, grasp point and pull out. If holder
doesn’t come out with the point, remove with pliers.
4. With locking pliers, push in new point and holder
aligning bolt hole in point with holes in auger shaft. DO
NOT damage end of point.
NOTE: When installing holder in auger shaft, edges of
holder may shave off.
5. Insert retaining bolt and tighten with nut.
6. Re-attach both blades and put blade protector back on.
AUGER
SHAFT
NUT
HOLDER
BOLT
BOLT
HOLE
POINT
LOCATING
HOLE
19437-0004R1
CAUTION
AVOID INJURY! DO NOT ATTEMPT TO START THE
ENGINE USING STARTING FLUID.
AVOID INJURY! DO NOT SPRAY FLAMMABLE
LIQUIDS OR VAPORS INTO AIR CLEANER,
CARBURETOR OR SPARK PLUG CHAMBER.
AVOID INJURY! DO NOT REMOVE SPARK PLUG
AND PULL STARTER ROPE. FLAME CAN SPRAY
OUT & IGNITE FROM A SPARK FROM SPARK PLUG.