2. TRS input

 – this jack accepts TRS input connections, either balanced or unbalanced. For 

balanced connections, a 3-conductor TRS plug is necessary. The TRS input is wired like this: 

INPUT SIGNAL 

TRS CONNECTIONS 

+ Tip 

- Ring 

Shield Sleeve 

 

 

Unbalanced wiring works with either a 2- or 3-conductor TRS connector. A 2-conductor TRS plug 
(or sometimes also just called TS plug) automatically grounds the minus signal input, whereas a 3-
conductor TRS plug wired unbalanced provides the option of leaving the minus open or grounded. 
We recommend that you ground the unused part. 

3. vent port

 – uniK plus is a vented box speaker system with a vent port on the rear panel. Because 

of this, it is better to keep some small distance from the wall and not to put the speaker directly into 
a corner of the room (as the two sides of the corner would generate different reflections). One 
option to deal with this in case it cannot be avoided or if it is your preference, you can close the vent 
port with the included ESI Bass Port Plug

TM

 (described in section 3.7) that ships with uniK plus. 

4. gain level adjustment

 – use this gain control knob to adjust the speaker properly to the input 

level from the sound source. Make sure to setup all speakers accordingly. When set to 0 (middle 
position), the input level is set to the recommended calibrated level to reach the most optimised 
dynamic response on the output (based on a a balanced XLR or TRS signal with +4dBu reference 
level). 

5. character selection (room adjustment)

 – via the character selection it is possible to tilt the 

whole frequency spectrum up (

BRIGHT

) or down (

SMOOTH

). This allows you to adjust the sound 

according to the requirements in your room as well as to your own hearing preferences and 
requirements. 

 

When set to 0 (middle position), the frequency response is optimised, i.e. as linear as possible. 
When the value is tilted upwards, the higher frequencies will appear stronger, yet the whole 
frequency spectrum will match accordingly. When the value is tilted downwards, the high 
frequencies will appear less strong. It is recommended to adjust the 

CHARACTER

 first, before you 

change something on the 

LOW

 and 

HIGH

 knobs. Also make sure that each speaker has exactly the 

same settings. 

6. high frequencies (room adjustment)

 – the 

HIGH

 knob allows you to adjust the high frequencies 

via a built-in EQ mostly affecting the area around 10kHz, by around 1dB for each step up or down, 
according to local requirements and your taste. 

Содержание Unik Pus

Страница 1: ...Professional Active Reference 5 and 8 Studio Monitor User s Guide...

Страница 2: ...ESI Copyright 2014 Revision 1 September 2014 www esi audio com...

Страница 3: ...2 0 Positioning 6 3 2 Stereo with Subwoofer 2 1 Positioning 6 3 3 Surround 5 1 Positioning 7 3 4 Surround 7 1 Positioning 7 3 5 Orientation 8 3 6 Additional Comments 8 3 7 ESI Bass Port PlugTM for ven...

Страница 4: ...igh resolution high and low switches add additional control and of course there is the option to utilize our ESI Bass Port PlugTM for further room adjustment i e to control the low frequencies in smal...

Страница 5: ...sure the power of the monitor is switched off before you connect any audio cables XLR balanced connection Connect male side of XLR balanced cable to the balanced XLR input of uniK plus Make sure the p...

Страница 6: ...owing diagram to understand how to position your monitors Each distance x should be identical 3 2 Stereo with Subwoofer 2 1 Positioning In a stereo setup with an added subwoofer the subwoofer speaker...

Страница 7: ...should be positioned around 110 from the center speaker all with the same distance x 3 4 Surround 7 1 Positioning In a 7 1 surround set the center speaker should also ideally be placed on top of the s...

Страница 8: ...a vent port that is conveniently placed on the backside of the unit making sure that air does not get blown into your face when you listen in a near field situation and to make sure that parasitic fre...

Страница 9: ...reduce unwanted vibrations depending on where exactly the speaker is placed They can individually be adjusted by turning them in and out or they can be removed altogether if you prefer not to use them...

Страница 10: ...near field operation ESI Bass Port PlugTM removed Ground lift switch Standby function can be turned on and off Indicator multi color LED on front panel power on orange standby red over load red flashi...

Страница 11: ...ight separately Working Voltage AC100 240V 50 60Hz Dimensions W x H x D 252 x 352 x 319mm Weight 8 1 kg 4 3 Rear Panel The following picture shows the rear panel of uniK 05 The functions of uniK 08 ar...

Страница 12: ...to adjust the speaker properly to the input level from the sound source Make sure to setup all speakers accordingly When set to 0 middle position the input level is set to the recommended calibrated l...

Страница 13: ...OFF This allows you in some situation to reduce or remove unwanted hum noise when there are issues with grounding of your audio signals in your studio setup 9 standby switch you can turn the standby...

Страница 14: ...marks of their respective companies Correspondence For technical support inquiries contact your nearest dealer local distributor or ESI support online at www esi audio com Disclaimer All features and...

Отзывы: