5. volume control knob

 – use the volume control knob to set the proper input level from the sound 

source. Make sure to setup the left / right speakers accordingly. 

6. high frequency level selection

 – this rotary switch allows you to change the level of the high 

frequencies in the signal to control room dumping in the range -2 to +1 dB in 1dB steps. Depending 
to your specific listening environment whether they  require such a change, you can adjust it here. 
The recommended default is the 0dB setting. 

7. low frequency boost selection

 – this rotary switch allows you to change the level of the low 

frequencies in the signal great for tuning the nEar08 if you are using a separate subwoofer like the 
ESI SW10K eXperience. 

8. power switch 

– when you push the power switch, nEar08 classic will be turned on, and 

–surprise– it will be turned off when you push the power switch again. 

9. power port with ext. fuse

 – use this connector to plug in the detachable 3-circuit line cord that 

connects to the power outlet. The connector also contains the mains fuse for protection. 

5. General Information 

Trademarks 

ESI, nEar, nEar08, nEar08 classic and SW10K eXperience are trademarks of EGOSYS, Inc. and 
ESI Audiotechnik GmbH. Other product and brand names are trademarks or registered trademarks 
of their respective companies. 

Correspondence 

For technical support inquiries, contact your nearest dealer, local distributor or ESI support online at 
www.esi-audio.com. 

Disclaimer 

All features and specifications subject to change without notice. 

Parts of this manual are continually being updated. Please check our web site www.esi-audio.com 
occasionally for the most recent update information. 

Declaration of Conformity (for the European Union) 

The product described in this manual is manufactured in China by 

ESI Audiotechnik GmbH, 

Brennerstraße 48, D-71229 Leonberg, Germany

. The product is labelled with the CE mark and 

conform to the protection requirements of the European Electromagnetic Compatibility Standards 
and Directives. The product is designed and constructed such that electromagnetic disturbances 
generated do not exceed levels allowing radio and telecommunications equipment and other 
equipment to operate as intended, and, the product has an adequate level of intrinsic immunity to 
electromagnetic disturbance to enable operation as specified and intended. 

The product is marketed as 

ESI nEar08 classic

 studio monitoring speaker. 

Содержание nEar08 classic

Страница 1: ...Professional 8 Studio Reference Monitors User s Guide ...

Страница 2: ......

Страница 3: ... Installation 4 Unpacking Handling 4 Connection 4 3 Placement of the speakers 5 Positioning 5 Orientation 5 Comments 6 4 Technical Data 6 Specifications 6 Rear Panel 7 5 General Information 8 ESI Copyright 2008 Revision 1 November 2008 www esi audio com ...

Страница 4: ...eave the monitors resting in the packaging foam Make sure that you don t grab the speaker driver units on the front to avoid damage Now check the monitors for signs of damage that might have occurred in shipping In the unlikely event of this please contact the reseller of the product immediately Be careful when you remove the packaging foam Please keep all packing materials Connection High quality...

Страница 5: ...tioning In principle two units and the listener should be positioned or aligned in a regular triangle form Please refer to the following diagram to understand how to position your monitors The height of the units more precisely the top of the woofer is recommended to be at the ear level of the listener Keep in mind that in a typical monitoring environment you are sitting in front of your workstati...

Страница 6: ...h ferro fluid Frequency Response 40Hz 24kHz LF Amplifier Power 70W HF Amplifier Power 70W S N Ratio 100dB below full output 20kHz Bandwidth Input Connectors 1 x XLR Balanced Input Connector 1 x TRS Balanced Unbalanced Input Connector Polarity Positive signal at input produce outward LF cone displacement Input Impedance 20k ohms balanced 10k ohms unbalanced Input Sensitivity 250 mV input produces f...

Страница 7: ...ve Unbalanced wiring works with either a 2 or 3 conductor TRS connector A 2 conductor TRS plug or sometimes also just called TS plug automatically grounds the minus signal input whereas a 3 conductor TRS plug wired unbalanced provides the option of leaving the minus open or grounded We recommend that you ground the unused input 3 serial number this label contains the product serial number 4 vent p...

Страница 8: ...r nEar08 nEar08 classic and SW10K eXperience are trademarks of EGOSYS Inc and ESI Audiotechnik GmbH Other product and brand names are trademarks or registered trademarks of their respective companies Correspondence For technical support inquiries contact your nearest dealer local distributor or ESI support online at www esi audio com Disclaimer All features and specifications subject to change wit...

Страница 9: ...afety requirements for mains operated electronic and related apparatus for household and similar general use EN55103 1 EN55103 2 Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use This declaration is made by Claus Riethmüller Managing Director _____________________ ______________ ___________________________ City Date Signature Leo...

Страница 10: ......

Отзывы: