ESI IVX 128 Скачать руководство пользователя страница 2

IVX 128 Plus upgrade guide 

 

8. 

Start Esi-Access again and connect to the IVX 128 being upgraded. 

9. 

Once the connection is established, click on the 

Maintenance

 item on the Esi-Access menu bar. 

Click on 

Send

, then click 

Software/Prompts

. The 

Software/Prompts

 window will appear (Figure 1). 

10. 

In the 

Software

 area of the window, select the 128_1108.bin file you copied in Step 6. Select the 

slot (2 or 3) into which you will load the software. 

Note:

  If you’re unsure of which slot to use, click on the 

Versions

 button at the lower right of the  

Esi-Access window. The contents of each slot will be displayed. Select an empty slot or, if 
both slots are occupied, select the slot with the oldest (lowest number) version. 

11. 

In the 

Run At

 field, select Power Cycle. Next, enter the 

Version

 number (1.10.8). (Refer to Figure 1.) 

 

Figure 1 

12. 

Click on the 

Send

 button. Click on 

Yes

 in the confirmation window. Esi-Access will now send the  

IVX 128 conversion program. 

13. 

When the software load has completed, power down the cabinet and power it up again. 

Wait for 

the phone displays to come back on

 (about 4–6 minutes) before continuing to the next step. 

14. 

In the 

Software

 area of the window, select the second .bin (128_2nnn.bin) file you copied in  

step 6. Select the same slot as in step 10 into which to load the software. 

15. 

In the 

Version

 area, enter the new version number (such as 2.11.nn). 

Example:

 If the second .bin file is named 128_2117.bin, enter 2 in the first box, 11 in the second 

box and 7 in the third box.  

16. 

In the 

Prompts

 area of the window, under 

Prompt Type

, click on 

Custom Prompts.

 You will see the 

prompt files you copied in step 7. Select 

all

 of these prompt files and click on the 

Add

 button. This 

will copy all of the selected prompts to the 

Prompts to Send

 list. 

17. 

Click on the 

Send

 button. Then click on 

Yes

 to confirm. Esi-Access will now send the IVX 128 Plus 

program and prompts. 

18. 

When Esi-Access displays the “Transfer complete” message, close Esi-Access and proceed to the 

Hardware Installation

 section on page 5. 

Содержание IVX 128

Страница 1: ...e installation Procedure 1 Using Esi Access to perform the upgrade Notes The following instructions assume that you are familiar with Microsoft Windows and Esi Access If you need more information on E...

Страница 2: ...send the IVX 128 conversion program 13 When the software load has completed power down the cabinet and power it up again Wait for the phone displays to come back on about 4 6 minutes before continuing...

Страница 3: ...pied which has the oldest lowest number version 6 Press 2 and Enter A new menu will appear RECEIVE SOFTWARE PROMPTS 2 Store Program in Slot 2 3 Store Program in Slot 3 4 Standard Prompts 8 Disconnect...

Страница 4: ...ple If the second bin file is named 128_2117 bin enter 2 11 7 followed by a space and the numeral 3 and then press Enter 22 Confirm your entry by typing Y and pressing Enter 23 A message will appear S...

Страница 5: ...cation You ll now need to identify the main board s assembly number in order to install the correct expansion memory SIMM 4 MB or 8 MB 1 Power down the cabinet and remove the top cover and port card 2...

Страница 6: ...inet Power up the cabinet 3 The system will initialize 4 Proceed to Restoration of programming page 7 Main board assembly 5010 0544 1 Remove the existing SIMM from the U13 connector Note Be sure to re...

Страница 7: ...2 Connect to the system using Esi Access 3 Clickon Restore and select the date and time of the backup to restore then clickon OK The system s configuration will be restored from the backup file 4 Onc...