IMPORTANT INFORMATION
P2
Always make sure all screws are tightened before use of the frame for desk.
Duty cycle of the frame for desk is 10%, max. 2 minutes operating / min. 18 minutes stop.
Maximum load of the frame for desk is
265 lbs (120 kg),
equally divided. Ensure the loading on each
column is less than
175 lbs (80 kg).
Otherwise it might cause permanent damage to the column(s)
during operation.
When the motor cable is connected to the control box, the columns can maintain an adequate locking
force up to
265 lbs (120 kg),
load on the table top. However, when the cable is damaged or is
disconnected from the control box, it will cause the desk sliding to the bottom within hours, if the load
on either columns are larger than
130 lbs (60 kg).
Make sure that no persons or items will collide with the frame for desk, when adjusting upwards and
downwards.
Damaged cords must to be replaced before connecting the main cable.
Keep at least
.80 inches (20 mm)
free space around the edge of whole frame/tabletop.
Do not operate the system where the temperature is outside the specified limits.
The frame for desk is not intended to be used as a person lift.
Do not pull or push the frame if moving. Make sure to avoid twisting the columns, by lifting the frame
above the floor when moving.
Min
Max
Frame Height
24.8 in (630 mm)
50.4 in (1280 mm)
Frame Width
34.0 in (864 mm)
64.0 in (1626 mm)
Foot Length
22.0 in (559 mm)
28.0 in (711 mm)
Anti Collision (Drive Back 40 mm)
U55 lbs (+25 kg)
Dow77 lbs (+35 kg)
Ambient Temperature
32 F (0 C)
113 F (45 C)
Column Height
23.2 in (590 mm)
Stroke
25.6 in (650 mm)
Max Load = Equally Divided
265 lbs (120 kg)
Max Load = Per Column
175 lbs (80 kg)
Speed = 0-100 Kg Load
1.42 in / sec (40 mm / sec)
Speed = 100 -120 Kg Load
1.57 in / sec (36 mm / sec)
Noise Level
39 dB
Duty Cycle
Max 2 min. run /18 min. stop - 10%
Rated Input
AC 100 - 240V 50Hz, 3A
Rated Output
32 V, Max 10A
Power Consumption In Standby
< 0.1 W
Power Consumption In Use
280 W
Lifetime
10,000 cycles
Safety functions
Overload protection
Overheat protection
Timeout/unbalance protection