What is a Channel Programmer?...

An explanation for householders

Introduction to the 3 Channel Programmer

T

his programmer can automatically switch your Central Heating or 

Hot Water ON and OFF up to 3 times a day, at whatever times you 

choose.   Timekeeping is maintained through power interruptions 

by a non replaceable battery designed to last for the lifetime of the 

programmer and the clock is automatically put forward 1 hour at 

1:00am on the last Sunday of March and back 1 hour at 2:00am on 

the last Sunday of October. The clock is factory pre-set to UK time 

and date, but you can alter it if you wish. During installation, the 

installer selects 24 hour, or 5 day/ 2day, or 7 day programming and 

2 or 3 on/off periods per day, via a 4 position DIP switch on the back 

of the unit (see installation instructions).
The large, easy to read display makes programming easy and the 

unit is designed to eliminate the possibility of accidental changes to 

your  programme.  Buttons  normally  visible,  only  affect  your  set 

programme temporarily. All buttons which can permanently change 

your programme are located behind the flip over facia.
- The 24 hour programmer option runs the same programme every 

day.
- The 5/2 Day programmer option allows different ON/OFF times at 

weekends.
- The 7 Day programmer option allows different ON/OFF times for 

each day of the week.
-  Pumped  System  (PU)  allows  independent  control  of  Central 

Heating and Hot Water.
- Gravity System (Gr) does not allow Central Heating without Hot 

Water but can provide Hot Water without Central Heating.

IMPORTANT: 

 These settings should only be changed by a qualified 

person. Contact your installer.  This programmer is not suitable for 

the switching of devices greater than 6Amp rated. (e.g. Not suitable 

for use as an immersion timer)

  

2

Содержание ES3247

Страница 1: ...ES3247 3 Channel Programmer User and Installation Instructions...

Страница 2: ......

Страница 3: ...ogramme 3 Changing the Programme 4 Linking Central Heating Hot Water Times 5 Operating the Unit Choosing the Operating Mode 5 Using the Advance Function 6 Using the HR Boost Function 7 Basic Settings...

Страница 4: ...tallation Safety Instructions Maintenance Safety Notice 11 Pre Installation Unit Set Up 12 Fitting the Back Plate 12 New Installations 13 Existing Installations 13 Wiring Diagram 14 Fitting the Progra...

Страница 5: ...User Instructions...

Страница 6: ...me for example Override Advance or Boost These are explained in the manufacturer s instructions The heating will not work if the room thermostat has switched the heating o And if you have a Hot Water...

Страница 7: ...large easy to read display makes programming easy and the unit is designed to eliminate the possibility of accidental changes to your programme Buttons normally visible only a ect your set programme t...

Страница 8: ...onday You can go to any day of the week by pressing the DAY button repeatedly The COPY button will copy the current programme onto the next day NB It is not possible to copy Sunday to Monday For 5 2 D...

Страница 9: ...mes 1 3 6 7 5 2 4 Fig 1 4 Press SET button 1 until tap icon 7 ashes in the display and 1 ON 3 appears This indicates the time shown on the display is the rst ON time Proceed in same manner as To chang...

Страница 10: ...will a ect both Central Heating and Hot Water and second Central Heating channel in 3 channel programmers To link the programmes hold down the COPY button whilst pressing RESET To switch the linked o...

Страница 11: ...Heating ON if it is in an OFF period and OFF if it is in an ON period It will stay in this state until either the ADV button 1 or 2 on g 2 is pressed again or until a programmed ON OFF period commenc...

Страница 12: ...out having to change the programme or use the ON or OFF buttons NB The HR function is only available when the programme is in AUTO ALL DAY or OFF operating modes If the programmer is in AUTO or ALL DA...

Страница 13: ...ime will change quicker if pressed continually 4 Press SET 1 once to move on to setting the DATE or press multiple times to return to RUN mode Setting the Date refer to g 4 1 Press the SET button 1 un...

Страница 14: ...OFF When the backlight is permanently OFF the backlight will turn ON for 15 seconds when or button is pressed then turn OFF automatically To change setting to permanently ON press SET repeatedly until...

Страница 15: ...Installation Instructions...

Страница 16: ...Technical Data 10...

Страница 17: ...earth throughout the system If the unit is tted to a metal surface IT IS ESSENTIAL that the metal be earthed DO NOT use a surface mounting box NEVER t or remove the unit to a live wall plate Maintenan...

Страница 18: ...mm min clearance to its right 25mm min above 90mm min below Ensure that the supporting surface will fully cover the back of the programmer 2 O er the back plate to the wall in the position where the p...

Страница 19: ...Stats etc are general representations only However the wiring detail can be applied to the corresponding model of most manufac turers e g Horstmann Honeywell Danfoss Randall Drayton ESi Controls etc...

Страница 20: ...14 Wiring Diagram...

Страница 21: ...accordance with customer requirements 3 Normally unit will be left with channel in Auto mode Fitting the Programmer 1 Loosen the two captive retaining screws on the bottom of the back plate 2 Now t t...

Страница 22: ...day programming options as set up by the installer can also be veri ed at this stage by how the Monday to Sunday indicators are displayed In the interests of continuous product improvement we reserve...

Страница 23: ......

Страница 24: ...Version 3 1 ESi Controls Limited sales esicontrols co uk www esicontrols co uk...

Отзывы: