14
N.B.
It is recommended to leave this setting in the default
OFF mode as heat generated by the thermostat’s power
supply and LED will affect temperature measurement.
A deviation of up to 3.5°C may occur, which will be
calibrated automatically by the unit within 30 minutes
of first connecting the thermostat. It is recommended
to leave the thermostat to climatise for 40 minutes
before user operation. If set permanently ON, the light
will automatically switch to a lower light setting and be
dimmer.
4.3
Resetting the Unit (rESE)
Resetting the unit will return the thermostat to default
setting. The time, date and landlord service settings will all be
maintained.
1.
Press
and
hold
until the display shows
tInE
. Turn the
dial until display shows
rESE
then
press
.
2. The display will show - - - -.
Press
again to confirm and
the display will show
LOAd
. If the reset is successful, the
unit will return to the homescreen after 2 seconds. If the
reset is unsucessful, the unit will display
FAIL
. Either
press
to attempt again or
press
to return to the
previous menu.
ESRTP5WIFI_User_instructions_AW.indd 14
17/06/2019 13:43