LED display 

The module has two LED displays. The function of the displays is explained in the following 

 

Display 

Label 

Function

 

LED Green 

Power 

Display for supply voltage via external power adapter 

LED Green 

Data 

 

Flashes in the case of 1-Wire activity 

 

Permanently flashes in the case of the 1-Wire Data Line short-
circuit

 

 

Software  

We recommend the use of the latest FTDI- and TEMX driver. We do not recommend the use of any driver that 
has beta status. Once the FTDI driver is installed, the 1-Wire Bus Coupler with USB interface is available as  
software-based serial bus coupler. The 1 Wire Bus Coupler USB can be operated with any software, that is 
aligned to operate the COM Port a

dapter „DS9097“. 

The 1-Wire Bus Coupler is being operated with 9600 Baud and settings of 8 data bits, no parity and 1 stop bit. As 
1-Wire interface for the 1-Wire Bus Coupler a Maxim Chip DS2480 is used. 
 
The 1-Wire Bus Coupler was tested with the following software: 
IP-Symcon, 1-Wire Viewer (Windows), FHEM 

Note:

 

The „Strong Pullup“ function must be activated. 

 

10 

USB-Connection cable 

Please note, that the cable length is limited to 5 m in maximum for the USB data cable among the 1-Wire Bus 
Coupler and the PC interface. To bridge USB cable sections of 30 to 50 meters, USB long distance extension 
cables are offered in our webshop. These long distance extension cables use a CAT5, CAT6 or CAT7 network 
cable for data transfer. This network cable cannot be connected with a TCP/IP network or a hub/switch network.  
 

11 

Windows power management for USB ports 

As soon as the Virtual Com Port Driver is installed, the 1-Wire Bus Coupler USB may break down after several 
hours of operation. This may be caused by the Windows Power Management settings for USB ports. The 
energy saving mode is activated in Windows basic settings. To operate the 1-Wire Bus Coupler USB, these 
settings must be deactivated. 
In Windows7, WHS and Server 2008, the drivers are to be installed with admin rights. 

 

Windows 7 Energy Options 

You will find the Windows 7 energy options under:

 

Start / Control Panel / Energy Options 
 
Windows 7 offers two options: 

Balanced 

and 

Energy saving 

mode

. The recommended mode is 

Balanced

 where it 

focusses on PC performance (not energy saving). Under 

Advanced Settings,

 you have several setup options. 

 
USB, Setup for selective operation:

 

Uncheck the box. The port will then be permanently 
enabled. 

 

In addition 

we recommend the use of the „Presenter View“ as 

the computer will operate with no screensavers. Further 
information can be found at: 

http://www.thewindowsclub.com/presentation-settings-in-
windows-7

 

 
   

 

 

 

Содержание 11302-U

Страница 1: ...y be enhanced Issues caused by unreliable USB voltage supplies will be avoided The use of more expensive USB hubs is no longer necessary The 1 Wire output of the bus coupler is isolated among the USB data supply and the voltage supply Thus ground loops or EMC emissions and grounding issues from a computer to the 1 Wire network are efficiently prevented The isolation significantly reduces stray rad...

Страница 2: ...ximally 500mA USB Interface Connection USB type B connection jack Interface USB 1 1 FTDI 232RL Chip 4 Ambient Conditions Temperature operation 0 C up to 60 C Air humidity 10 92 non condensing Dimensions 35 x 90 x 70mm WxHxD Protection class III Protection type IP20 Insulation 500 VAC output to 1 Wire Bus 250 VAC output to output 5 Conformity EN 50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4...

Страница 3: ...written consent of ESERA Automation or E Service GmbH Errors and technical modification subject to change ESERA Automation E Service GmbH 2019 www esera de 11302 U V1 5 R1 2 Manual Page 3 of 6 Art No 11302 U 7 Connection Example Combination of 1 Wire Bus Coupler 1 Wire Hub III top hat rail case sensor and bus terminator ...

Страница 4: ...be activated 10 USB Connection cable Please note that the cable length is limited to 5 m in maximum for the USB data cable among the 1 Wire Bus Coupler and the PC interface To bridge USB cable sections of 30 to 50 meters USB long distance extension cables are offered in our webshop These long distance extension cables use a CAT5 CAT6 or CAT7 network cable for data transfer This network cable canno...

Страница 5: ...installation they must not have power applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged Live cables or wires to which the device or an assembly is connected must always be tested for insulation faults or breaks If an erro...

Страница 6: ...original purchase price refunded or a reduction of the purchase price ESERA Automation accepts liability neither for the constant and uninterrupted availability of the ESERA Automation or for technical or electronic errors in the online offer We develop our products further and we reserve the right to make changes and improvements to any of the products described in this documentation without prio...

Отзывы: