Connection plan 

The connection plan is available in our web shop  
as a separate document. 

Note: A back-up fuse must be provided for  
terminal 14 with 10A. 
 
Connection module top side:

 

14 = Current input 
15 = Output 1, make-contact 
16 = Output 2, make-contact 
17 = Output 3, make-contact 
18 = Output 4, make-contact 
19 = Output 5, make-contact 
20 = Output 6, make-contact 
21 = Output 7, make-contact 
22 = Output 8, make-contact 
 

 
Module bottom side: 
1-Wire Bus 

10 = +12V external voltage* (optional) 
11 = GND (ground) 
12 = 1-Wire data line 
13 = +12V voltage 

 

*

 

If the Bus system is not able to supply the module 

with sufficient power, an external 12V power supply 
can be connected as support.  
This power supply unit must not be used to supply 
non-Bus modules. 

 

 

 

Conformity 

EN 50090-2-2,  
EN 61000-4-2, ESD 
EN 61000-4-3, HF 
EN 61000-4-4, Burst 
EN 61000-4-5, Surge 
EN 61000-6-1, Fault-free operation 
EN 61000-6-3, Stray radiations 
RoHS 

 

Operation mode, display 

After the device has been put into operation, all LEDs of the relay outputs will light up briefly. From this moment 
on, the 8-fold switch module is ready for operation and switching commands can be sent via the 1-wire interface. 
The corresponding status LEDs of the active relays will light up. 
 

Display 

Designation 

LED function 

LED 1-8 

Output 1-8 

-  LED lights up for 2 seconds to start the system 
-  LED indicator lights up when the respective output is active 

LED PWR 

Power 

-  LED flashing lights up 2 seconds to start the system 
-  LED display for operational readiness 

LED Status 

Status display  

-  LED lights up for 2 seconds to start the system 
-  Flashes when controlled via the bus interface 

 
 