Storage of counter values / Delete counter values 

The counter reading of the Dual S0 counter module is stored permanently, even without power supply. 
The  counter  reading  can  be  set  to  0  by  pressing  the  reset  button  for  approx.  3  seconds.  In  order  to  avoid  an 
accidental reset of the counter reading, the reset button is recessed on the top of the module. To operate the reset 
button, you need a pointed object, such as a match or toothpick.   

 

17 

Operating conditions 

The module may only be operated at the specified voltages and ambient conditions. The device can be operated 
in any position. The device is intended for use in dry and dust-free rooms.  
If condensation is formed, allow at least 2 hours for the unit to acclimatize. 
The modules may only  be  put into operation  under the supervision of a qualified electrician. Do not  operate the 
module in an environment in which flammable gases, vapors or dust are present or could be present. 
 

18 

Assembly 

The installation site must be protected from moisture. The device may only be used in dry indoor areas. The device 
is intended for installation inside a control cabinet as a stationary device. 
 

19 

Disposal instructions  

Do not dispose of the device in domestic waste! Electronic devices are to be disposed of according to  
the Directive on waste electrical and electronic equipment (WEEE) on local authorities and 
collection points for waste electronic equipment! 

 

20 

Safety Instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be 
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the 
mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact 
proof housing. During installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices 
are disconnected from the power supply and electrical charges stored in the components inside the device have 
been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable 
has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics 
for a part or assembly are, how to connect an external circuit, which external components or additional devices can 
be connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or 
disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be 
installed upstream or a suitable power supply can be used.  

 

After installation the required tests according to DGUV / regulation 3 (German statutory accident insurance, 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

must be carried out. 

 

Содержание 11211

Страница 1: ...lectricity water and gas meters or wind turbines All S0 devices manufactured according to DIN 43864 can be equipped with an isolated S0 interface can be connected If in doubt check the data sheet of your energy measuring device After applying the operating voltage the Dual S0 counter module is ready for operation The integrated Counter modules count the input pulses continuously The counter readin...

Страница 2: ... 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Interference immunity EN 61000 6 3 Interference radiation RoHS 6 LED display The module has two yellow LED displays which flash when an input is being closed When the input is open a 5V power is measurable The edge is being counted during the closing of the input A continuously closed input does not cause a modification of the counter read...

Страница 3: ...und for example on the Wikipedia website https en wikipedia org wiki Electricity_meter https de wikipedia org wiki S0 Schnittstelle 10 Data output 1 Wire Controller 1 Wire Gateway For the Dual S0 counter module the following data of the 32Bit counter values are output The 1 Wire interface of the Dual S0 counter module is controlled by standard commands for the DS2423 block and the data is read out...

Страница 4: ...written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11211 V2 0 R1 0 Manual Page 4 of 7 12 Connection example 1 Combination of AC meter and Dual S0 counter module 13 Connection example 2 Combination of three phase meter and Dual S0 counter module ...

Страница 5: ...echnical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11211 V2 0 R1 0 Manual Page 5 of 7 14 Connection example 3 Combination of wind sensor and Dual S0 counter module 15 Connection example 4 The following example shows the combination of 1 Wire Controller 20 1 Wire Gateway 20 Modbus 1 Wire Analog Input Module and 1 Wire S0 Dual Counter Module ...

Страница 6: ...r applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged Live cables or wires to which the device or an assembly is connected must always be tested for insulation faults or breaks If an error is detected in the supply line the...

Страница 7: ...urchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We are constantly developing our products further and reserve the right to make changes and improvements to any of the products described in this documentation without prior notic...

Отзывы: