9910046 RevJ June 2022
PAGE
21
Appendix B: Ratings
Fire Rating:
The cFR system has a CLASS A SYSTEM FIRE RATING PER UL 2703
•
Low Slope Roofs (2:12 or less) with Module Types 1, 2, 16, 19, 22, 25, 29, and 30
•
Wind Deflector is not required for Dual Tilt to maintain Class A System Fire Rating
•
Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating.
UL 2703 Listing:
ClawFR 10 Degree Dual Tilt conforms to STD UL 2703 (2015) Standard for Mounting Systems, Mounting Devices,
Clamping/ Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels and
Certified to CSA TIL No. A-40.
•
Max Overcurrent Protective Device (OCPD) Rating: 40A
•
Max Module Size: 36.8 ft
2
•
Module Orientation: Landscape
•
System Design Load Rating: 30psf downward, 30psf upward, 5psf lateral
•
Actual system structural capacity defined by the PE stamped calculation package and racking construction set