Hardware Installation
4. Hardware Installation
NOTICE
Read the safety instructions at the beginning of this document carefully, before
you start with the hardware installation!
DANGER
Hazardous Voltage -
Risk of electric shock
due to unintentional contact with
uninsulated live parts with high voltages inside of the system into which the CPCI-
CAN/402-4(-FD) is to be integrated.
→ Disconnect all hazardous voltages (mains voltage) before opening the system.
→ Ensure the absence of voltage before starting any electrical work
NOTICE
Electrostatic discharges may cause damage to electronic components.
→
→
To avoid this, please discharge the static electricity from your body by touching the
metal case of the CompactPCI system
before
you touch the CPCI-CAN/402-4(-FD).
Furthermore, you should prevent your clothes from touching the CPCI-CAN/402-4(-
FD), because your clothes might be electrostatically charged as well.
Procedure:
1.
Switch off your system and all connected peripheral devices (monitor, printer, etc.).
2.
Discharge your body as described above.
3.
Disconnect the system from the mains.
DANGER
Hazardous Voltage
Risk of electric shock
due to unintentional contact with uninsulated live parts with
high voltages.
→
→
→
→
Disconnect all hazardous voltages (mains voltage) before opening the system.
If the system does not have a flexible mains cable, but is directly connected to
mains, disconnect the power supply via the safety fuse and make sure that the
fuse cannot switch on again unintentionally (i.e. with caution label).
Ensure the absence of voltage before starting any electrical work.
Cover or block off adjacent live parts.
4.
Open the case if necessary.
5.
Set the jumpers for the internal termination of the CAN (FD) interfaces according to your
needs (see page 13).
6.
Insert the CPCI-CAN/402-4(-FD) board into the selected CompactPCI slot. Carefully push the
board until it snaps into place.
7.
Attach the CPCI-CAN/402-4(-FD) board.
8.
Connect the CAN or CAN FD interfaces via the DSUB25 connector in the front panel of the
CPCI-CAN/402-4(-FD).
You can use the cable CAN/400-4-1C4 by esd (see Order Information, page 41) as adapter
from the DSUB25 connector to 4 DSUB9 connectors.
Page 14 of 42
Hardware Manual • Doc. No.: I.2332.21 / Rev. 1.2