iMiniPlus PDF Logger User Guide v2.0 

 

 

- 16 - 

The  Program  and  Configure  process  will  only  continue  successfully  if  the 
correct password is supplied by the user. Passwords are digits only, up to 4 
characters. 
You  can  enter  a  password  to  safeguard  your  logger  from  unauthorized 
tampering.  Make  sure  that  you  keep  a  note  of  your  password  and  logger 
serial number in a safe place. If you lose or forget the password, the logger 
will  have  to  be  returned  to  your  nearest  distributor  or  Cryopak  to  restore 
default password. 
 
 

Change Password

 – if you have password protected the iMiniPlus PDF 

Logger or want to add a password for the first time you can do this here. 

 

Protect program settings - 

Tick this option if you want to protect your 

programming settings for the current logger. 

Protect retrieval of readings- 

Tick this option to disallow viewing of data 

from the current logger without a password. 

After complete the password section, click 

OK

 

Select the 

Next

 button or 

Sensors

 tab. 

 

9.3

 

Configure Sensors and Alarm Settings 

 

 

 

 

 

 

 

 

 

Sensors  Tab  – 

this  displays  the 

sensor  information  some  of  which 
can be changed  by  using Configure 
Sensor(s)  and  others  that  remain 
fixed  i.e.  range  -40

C  to  70

C.  The 

description 

“Internal”

  refers  to  the 

type  of  sensor  as  opposed  to 

“External

” which will display on the 

external sensor model. 

 

Configure Sensor(s)…

 

 click on this 

button to set up the alarm and LCD 
display parameters. 

 

Содержание iMiniPlus PDF

Страница 1: ...iMiniPlus PDF User Guide Version 2 0...

Страница 2: ...6 9 3 1 Specification and Alarm 17 9 3 2 LCD Display 18 9 4 Checking the time clock 19 9 5 Setting the Start Stop and logging duration 19 9 5 1 Duration of trip at least 19 9 5 2 Interval between each...

Страница 3: ...ning logger data to make a decision on accepting or rejecting the shipment 3 Logger profile The iMiniPlus PDF Logger is available in two models Both have the same temperature range of sensor D range 4...

Страница 4: ...your distributor for a replacement When replacing the battery align one triangular mark on the battery cover against similar shaped mark on the logger base to avoid damaging plastic lock feature of th...

Страница 5: ...r communication purposes with software LRF file is used by Console Pro to create secure LCF file for traceable data records iMiniPlus PDF Logger does not consume battery power when connected to USB an...

Страница 6: ...r of the logger Hardware version this is actually firmware version Description string programmed to the logger by Console Pro Battery status last measured by the logger before it has been connected to...

Страница 7: ...d on readings retrieved from logger memory and result may be different Lowest temperature reading for the current trip High Alarm status Low Alarm status Both High and Low Alarm can have the following...

Страница 8: ...t to 20 C Note that the graph contains coloured dashed lines for primary alarm limits and solid coloured lines for catastrophe alarm limits Note that the numerical values of the alarm limits are not s...

Страница 9: ...trip This part of the report can be disabled when programming You can change date display format to display month first by programming logger Date and Time is displayed along the X axis Temperature v...

Страница 10: ...be read as Logger has spent 49 minutes and 40 seconds between 25 C and 25 9 C in this case the value of 1 degree per report line is configured by programmable parameter named Increment Note if Fahrenh...

Страница 11: ...ways has two columns This part of the report can be disabled when programming You can change date display format to display month first by programming logger Marked readings are displayed with asteris...

Страница 12: ...r The cable has two different ends The smaller one is type Mini B and the bigger one is type A Connect USB cable with Mini B smaller connector to the logger and A size to PC or laptop computer as illu...

Страница 13: ...to use Console Pro Professional version 2 12 07 or later to program the logger Check this check box and click on Program and Configure button on the toolbar Program Wizard should start Then click Next...

Страница 14: ...report that can be several pages long depending on the number of readings If you uncheck Create PDF file checkbox the logger will not generate PDF report at all You may need this option to prevent unw...

Страница 15: ...year format by choosing one option from drop down box on this tab as shown below 9 2 Programming password The iMiniPlus PDF Logger supports a password option that when enabled results in users being...

Страница 16: ...to add a password for the first time you can do this here Protect program settings Tick this option if you want to protect your programming settings for the current logger Protect retrieval of reading...

Страница 17: ...eturn inside alarm limits the consecutive alarm is reset Total number of out of specification readings cumulative the alarm is triggered if the total number of out of spec readings equals or exceeds t...

Страница 18: ...N 4 19 OFF 0 OFF 2 OFF 4 ALARM ON 5 21 OFF 1 OFF 3 OFF 5 ALARM ON 6 22 OFF 2 OFF 4 OFF 7 ALARM ON 7 24 OFF 3 OFF 5 ALARM ON 11 ALARM ON 8 22 OFF 4 ALARM ON 6 ALARM ON 13 ALARM ON 9 21 ALARM ON 5 ALARM...

Страница 19: ...ent for instance you have the option of setting up the parameters yourself or let the Console Pro software calculate these automatically for you Thesoftware takes thetotal memory available 8048 readin...

Страница 20: ...iMiniPlus PDF Logger User Guide v2 0 20...

Страница 21: ...on the LCD You can also enable the STOP button on the logger This is disabled by default because in most applications it is better to take too many readings than too few Downloading the logger readin...

Страница 22: ...utton If the upload has failed either select the Cancel button to close the software and start again or select the Restart button to start the sequence again If the iMiniPlus PDF Logger still fails to...

Страница 23: ...ve the data from an iMiniPlus PDF Logger both of which will achieve the same result 1 Click the Download Information icon on the toolbar 2 Click the Download Information item located under the Action...

Страница 24: ...application Otherwise leave the Logger option at its default setting Do not upload any new start conditions to the logger s Click on the Finish button Readings and Summary is displayed Download Wizard...

Страница 25: ...d to communicate with the logger In other words you can email LRF files and Console Pro will create an LCF file from the LRF file Then you will be able to add digital signatures to the LCF file view d...

Страница 26: ...n menu The following dialog should be displayed Please ensure that file name is unique By default Console Pro assigns the logger s serial number and trip number to the name of the file Navigate to the...

Страница 27: ...and date Real time clock accurate to 1minute per month Sampling frequency 5 seconds 18hours Power source User replaceable 3V lithium coin cell Typical battery life 1 2 years operating life from a user...

Страница 28: ...our website www cryopak com http www cryopak com en verification products Mailing Address PO Box 309 Buchanan VA 24066 Office 120 Parkway Drive Buchanan VA 24066 Phone 1 540 254 1433 1 732 346 9200 Ex...

Отзывы: