Escea DL850 Скачать руководство пользователя страница 5

2. 

Basic Operation

 

− Initial Start / Battery Placement

Remove the battery cover on the rear of the remote. Insert the new “AA” size batteries, being careful of 

the polarity. You should now see on the display of the remote the time showing “0:00”. To turn the fire 

on, press the “POWER” (2) button once, and within a few seconds the appliance will begin its startup 

sequence.

NOTE: The appliance begins its startup with a fifteen second pre-ignition purge, where the combustion fan runs 

on its own before it tries to ignite. Between ignition attempts the remote will alternately show the remote’s “Set” 

temperature and a rotating segment indicator to show that the fire is in start up mode and will try to ignite 

again.

 

− Adjusting the Room Temp

To set the room temperature, press the ‘plus’ (8) or ‘minus’ (4) buttons repeatedly until the display is show-

ing the desired temperature. The remote will then revert back to the ‘current’ room temperature after 30 

seconds. The lowest flame setting will run continuously whilst the medium and high settings will operate 

according to the temperature set by the remote.

 

− Fan Boost

The fire has four FAN SPEED settings. The first low fan speed will run automatically on start-up. The  

second and third fan speed will automatically switch on or off with the increase or decrease of the set 

temperature, and the forth fan speed is an optional FAN BOOST speed, which can be accessed on your 

remote. Pressing the FAN BOOST button (7) will increase the fan speed to its maximum. When this mode is 

not on, the fire will still use fan speeds one, two, and three. 

NOTE: The maximum flame setting will ONLY come on in Fan Boost mode.

 

− Effect Only

Pressing the EFFECT ONLY button (3) will only turn on the lowest setting on the front burner only. This 

mode is intended as an ambient effect, although some heat will still be produced, and the room air fan 

will operate at its lowest setting in this mode.

NOTE: The room air fan may continue to operate for a few minutes after the fire has been switched off to 

remove any excess heat.

3. 

Setting the Time

Press and hold the “SET TIME” button (6) for more than two seconds and this will allow you to set the hour 

including “AM” or “PM” using the PLUS (8) or MINUS (4) buttons.

Pressing the “TIME SET” button (6) again will allow you to set the minutes.

Press the button one more time to exit the “SET TIME” mode.

Содержание DL850

Страница 1: ...User Guide For the latest documentation visit www escea com 630160_1 DX1500 DL850 Gas Fireplace...

Страница 2: ...D SERVICED AT LEAST ANNUALLY BY AN AUTHORISED TECHNICIAN THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S WRITTEN INSTRUCTIONS THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHI...

Страница 3: ...4 Keylock 06 5 Timer Operation 06 Activate Timer De activate Timer 6 Auxiliary On Off Button 07 7 Over Temp Shutoff Operation 07 8 Sound and Smell 09 Sounds Fan Gas Control Valve Appliance Metalwork...

Страница 4: ...tatus of timers and other functions On Off Switches the appliance on and off Flame Effect Places the fire in a constant low output mode Minus Adjusts the temperature and time settings down NOTE The fa...

Страница 5: ...e set by the remote Fan Boost The fire has four FAN SPEED settings The first low fan speed will run automatically on start up The second and third fan speed will automatically switch on or off with th...

Страница 6: ...ill change the hour Pressing the TIMER SELECT button 5 again will make the minute figures start flashing You will continue to see the ON and the number 1 This indicates that you are currently editing...

Страница 7: ...Set temperature This is referred to as the Overtemp Shut Off Mode To enable Overtemp Shut Off Mode so the fire will turn off all burners when the Room temperature climbs above the Set temperature you...

Страница 8: ...he fire is switched off after being run for a while there may be popping and fluttering noises as the residual gas in the burner burns away These are normal and should be no cause for concern Applianc...

Страница 9: ...cleaner Cleaning maintenance will need to be carried out whenever soot builds up on the logs and or inside of the glass If soot build up becomes excessive or regular then it is recommended that you co...

Страница 10: ...e order and test run heater 10 Trouble shooting Escea gas fires communicate both to and from the fire and remote This enables the remote to provide some basic fault finding information that is useful...

Страница 11: ...in restricted air flow at the top of the fire Room air fans may be slowed or stalled Remove firebox check that fans are plugged in cleaned and free turning The gas regulator being set too high resulti...

Страница 12: ...dance with ESCEA operating and maintenance instructions then for the first period of 12 months from the date of purchase ESCEA will pay the cost of repairing or replacing any part of the Product that...

Отзывы: