6
TIMER ON Button
TIMER OFF Button
UP Button( )
Push this button to decrease the indoor
o
o
temperature setting in 1 C increments to 17 C.
DOWN Button( )
8
10
12
11
13
14
Press this button to initiate the auto-on time
sequence. Each press will increase the auto-
timed setting in 30 minutes increments. When
the setting time displays 10.0, each press will
increase the auto-timed setting 60 minutes
increments. To cancel the auto-timed program,
simply adjust the auto-on time to 0.0.
Press this button to initiate the auto-off time
sequence. Each press will increase the auto-
timed setting in 30 minutes increments. When
the setting time displays 10.0, each press will
increase the auto-timed setting 60 minutes
increments. To cancel the auto-timed program,
simply adjust the auto-off time to 0.0
Push this button to increase the indoor
o
o
temperature setting in 1 C increments to 30 C.
FOLLOW ME Button:
Push this button to initiate the Follow Me
feature, the remote display is actual tempera-
ture at its location. The remote control will
send this signal to the air conditioner every 3
minutes interval until press the Follow Me
button again. The air conditioner will cancel
the Follow Me feature automatically if it does
not receive the signal during any 7 minute
interval.
Swing Button
(applicable for RG52E1/BGEF)
Swing Button
(applicable for RG52E1/BGEF)
Used to stop or start horizontal louver move-
ment or set the desired up/down air flow
direction. The louver changes 6 degree in angle
for each press. If keep pushing more than 2
seconds, the louver will swing up and down
automatically.
Used to stop or start vertical louver movement
and set the desired left/right air flow direction.
The vertical louver changes 6 degree in angle
for each press. If keep pushing more than 2
seconds, the vertical louver auto swing feature
is activated.
1
1
2
2
4
4
5
5
3
3
9
9
8
8
10
10
6
6
7
7
11
11
12
12
13
14
14
ON/OFF
ON/OFF
MODE
MODE
FAN
FAN
SLEEP
TEMP
TEMP
ECO
ECO
TIMER ON
TIMER ON
TIMER OFF
TIMER OFF
LED FOLLOW ME
LED FOLLOW ME
TURBO SELF CLEAN
TURBO SELF CLEAN
9
Used to enter the energy efficient mode.
Under cooling mode, press this button, the
remote controller will adjust the temperature
O
automatically to 24 C, fan speed of Auto to
save energy(but only if the set temperature
O
is less than 24 C). If the set temperature is
O
O
between 24 C and 30 C, press the ECO
button, the fan speed will change to Auto,
the set temperature will remain unchanged.
NOTE:
Pressing the TURBO and SLEEP button,
modifying the mode or adjusting the set
O
temperature to less than 24 C will stop
ECO operation.
Under ECO operation, the set temperature
O
should be 24 C or more. it may result in
insufficient cooling. If you feel uncomfortable,
just press the ECO button again to stop it.
ECO Button:
RG52E1/BGEF
SLEEP FRESH
SWING DIRECT
SWING Button
(applicable for RG52E2/BGEF)
DIRECT Button
(applicable for RG52E2/BGEF)
Used to change the louver movement and set
the desired up/down air flow direction.
O
The louver changes 6 in angle for each press.
Used to stop or start horizontal louver auto
swing feature.
FRESH Button
(applicable for RG52E2/BGEF)
Active/Disable
When the
FRESH function is initiated, the Ionizer/
Plasma Dust Collector(depending on
models) is energized and will help to
remove pollen and impurities from the air.
FRESH function.
LCD Display
7
8
Indicators on LCD
Transmission Indicator
Temp./Timer display
Fan speed display
Sleep Display
Mode display
ON/OFF display
This transmission indicator lights when remote
controller transmits signals to the indoor unit.
Displays the current operation mode. Including
auto( ), cool( ), dry( ), heat( ) (be
applicable to cooling & heating models only ),
fan( ) and back to auto( ).
O
O
Displays the temperature setting(17 C~30 C). When
you set the operating mode to FAN, no temperature
setting is displayed. And
the ON and OFF settings of the TIMER.
if in the TIMER mode, shows
Displayed by pressing the ON/OFF button.
Press the ON/OFF button again to remove.
Displays the selected fan speed, AUTO(no display)
and three fan speed levels " " (LOW) " "
(MED) " " (HIGH) can be indicated.
The fan speed is AUTO when the operating mode is
either AUTO or DRY.
Displayed under sleeping operation.
Press the SLEEP button again to remove.
Note:
of clear presentation. But during the actual operation
only the relative functional signs are shown on the
display window.
All indicators shown in the figure are for the purpose
FOLLOW ME Display(on some models)
Displayed when FOLLOW ME function is activated.
TIMER ON display
TIMER OFF display
Displayed when TIMER ON time is set.
Displayed when TIMER OFF time is set.
How to use the buttons
Cooling /Heating/Fan operation
Ensure the unit is plugged in and power is
available.
1. Press the
MODE
button to select COOL,
HEAT(cooling & heating models only) or
FAN mode.
2. Press the
UP/DOWN
buttons to set the
desired temperature. The temperature can
O
O
O
be set within a range of 17 C~ 30 C in 1 C
increments.
3. Press the
FAN
button to select the fan speed
in four steps- Auto, Low, Med, or High.
4. Press the
ON/OFF
button to start the air
conditioner.
In the FAN mode, the setting temperature is not
displayed in the remote controller and you are not
able to control the room temperature either. In this
case, only step 1, 3 and 4 may be performed.
NOTE
Auto operation
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the
MODE
button to select Auto.
2. Press the
UP/DOWN
button to set the
desired temperature. The temperature can
O
O
O
be set within a range of 17 C~ 30 C in 1 C
increments.
3. Press the
ON/OFF
button to start the air
conditioner.
1. In the Auto mode, the air conditioner can logically
choose the mode of Cooling, Fan, and Heating
by sensing the difference between the actual
ambient room temperature and the setting
temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed.
It has already been automatically controlled.
3. If the Auto mode is not comfortable for you , the
desired mode can be selected manually.
NOTE
2
2
1
1
4
3
3
ON/OFF
MODE
ECO
ECO
FAN
TEMP
TIMER ON
TIMER OFF
LED FOLLOW ME
TURBO SELF CLEAN
ON/OFF
MODE
FAN
TEMP
TIMER ON
TIMER OFF
SLEEP
LED FOLLOW ME
TURBO SELF CLEAN
SLEEP
RG52E1 - UserManual_V1.indd 9
17/5/19 10:44 am