1. 

Slide the unit into the housing until it is firmly 

against the rear of the housing. Care is required 

to ensure the foam sealing strips on the housing 

remain in position.

2. 

Connect the air conditioner to the power and 

position excess cord length beneath the air 

conditioner base.

3. 

Engage the chassis fixing brackets into the bottom 

housing rail and secure to the base with the screw 

provided.

4. 

Remove the front panel from it’s carton and 

plastic bag and fit as per the Installation 

lnstruction.

5. 

Switch unit on. Check for operation of the unit 

and check for vibration in the installation.

6. 

Fit the drain pan to the housing and run a drain 

line to a suitable location if required.

INSTALLATION OF THE UNIT INTO THE WALL

 

 

 

INSTALLATION STEPS

Step 1. Remove the front panel and the air filter

1. 

Hold the slot under the front panel, then uplift it outwards, and remove the front 

panel (See Fig. 1).

2. 

Pinch the handle under the air filter and make the air filter arched, remove it 

from the slot from underside to upside (See Fig. 2).

Fig. 1

Fig. 2

Fig. 3D

Fig. 3C

Fig. 3B

Fig. 3A

Fig. 4

 

Step 2. Remove the frame

1. 

To meet different requirement of different type of air conditioner, there are four 

kinds of removing the frame.

•  Remove the two screws on the left and right chassis fixing brackets, then 

remove the two chassis fixing brackets as shown in Fig. 3A.

•  Remove one screw on the chassis fixing bracket, then remove the chassis 

fixing bracket. Remove the two screws located on the back of the cabinet 

as shown in Fig. 3B.

•  Remove one screw on the chassis fixing bracket, then remove the chassis 

fixing bracket as shown in Fig. 3C.

•  Remove the four screws located on both sides and the back of the cabinet 

as shown in Fig. 3D.

2. 

Grasp the left corner of the frame’s underside, release the coupler plugs, then 

loosen the frame (See Fig. 4). 

Содержание EWAC36RC

Страница 1: ...UserManual Exactly what you need Model Code s EWAC36RC Online esatto house Product Window Air Conditioner...

Страница 2: ...arnings Page 8 Your Air Conditioner Page 9 Operation Instructions Page 11 Installation Instructions Page 18 Troubleshooting Page 19 Specifications Page 20 Warranty Information Page 22 Receipt Page 19...

Страница 3: ...r disconnect the power supply to the unit if strange sounds smell or smoke comes from it It may cause fire and electric shock Do not use the socket if it is loose or damaged It may cause fire and elec...

Страница 4: ...nection must be incorporated in the fixed wiring in accordance with the wiring rules How to fix the appliance to its support please read the installation instructions section in this manual All wiring...

Страница 5: ...E SETTINGS DOWN Press the keypad to decrease the set operating temperature of the unit Each time the keypad is pressed the temperature decreases as follows 1 C Celsius Scale Minimum Setting 16 C FAN P...

Страница 6: ...a malfunction of the outdoor condenser temperature sensor Note When one of the above malfunctions occurs turn off the unit and check for any obstructions Restart the unit if the malfunction is still...

Страница 7: ...used Please seal it in case leakage is found Operation Instructions Continued Installation Instructions Bottom drain hole Rubber plug Drain outlet Dust pan Rubber plug Screw Back drain hole Bottom dra...

Страница 8: ...Remove the front panel and the air filter 1 Hold the slot under the front panel then uplift it outwards and remove the front panel See Fig 1 2 Pinch the handle under the air filter and make the air f...

Страница 9: ...r into the frame s slot from upside to underside See Fig 2 2 Hang the front panel on the frame s buckle then press the front panel into the frame s slot until you hear a click See Fig 9 Fig 8 Fig 9 Fi...

Страница 10: ...and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Air conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds...