SECTION 3
INSTALLATION
3-11
RECISION PLASMARC
PILOT
ARC
POWER
CONTR
OL
CURRE
NT
3.7 Torch Coolant
•
Remove coolant fill cap at front of console and fill
coolant tank with 4 gallons (15 liters) of plasma
coolant, P/N 156F05 (one gallon).
•
Do not fill above maximum level
•
Reinstall Cap.
CAUTION
!
Commercial Antifreeze Will Cause Torch To
Malfunction
Use Special Torch Coolant! P/N156F05
Due to high electrical conductivity, DO NOT use tap
Due to high electrical conductivity, DO NOT use tap
Due to high electrical conductivity, DO NOT use tap
Due to high electrical conductivity, DO NOT use tap
water or commercial antifreeze for torch cooling. A
water or commercial antifreeze for torch cooling. A
water or commercial antifreeze for torch cooling. A
water or commercial antifreeze for torch cooling. A
specially formulated torch coolant is REQUIRED. This
specially formulated torch coolant is REQUIRED. This
specially formulated torch coolant is REQUIRED. This
specially formulated torch coolant is REQUIRED. This
coolant also protects for freezing to –34° C.
coolant also protects for freezing to –34° C.
coolant also protects for freezing to –34° C.
coolant also protects for freezing to –34° C.
Operating the unit without coolant will cause
Operating the unit without coolant will cause
Operating the unit without coolant will cause
Operating the unit without coolant will cause
permanent damage to the coolant pump.
permanent damage to the coolant pump.
permanent damage to the coolant pump.
permanent damage to the coolant pump.
3.8 Inspection of Gas and Coolant Lines
To complete installation, it is necessary to inspect
field assembled connections for leaks.
•
Gas lines, use a standard soap solution.
Pressurize the system from the control (SDP file)
•
Coolant- check connections for signs of
moisture at connections
Coolant
Fill Cap
Содержание Precision Plasmarc
Страница 16: ...SECTION 1 SAFETY 1 10 This page intentionally left blank ...
Страница 20: ...SECTION 2 DESCRIPTION 2 4 Page intentionally left blank ...
Страница 122: ...SECTION 4 OPERATION 4 88 Page intentionally left blank ...
Страница 144: ...SECTION 6 TROUBLESHOOTING 6 12 E2 E2 G2 E1 G1 C1 C2E1 C x Q x 4 6 9 Precision Plasma Power Module Schematic DETAIL ...
Страница 182: ...SECTION 7 REPLACEMENT PARTS 7 2 1 2 3 4 5 6 7 8 7 3 Plasmarc Power Source Exterior Components ...
Страница 184: ...SECTION 7 REPLACEMENT PARTS 7 4 1 2 3 4 5 6 7 8 9 10 11 See TEE Detail Page 7 12 ...
Страница 186: ...SECTION 7 REPLACEMENT PARTS 7 6 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 190: ...SECTION 7 REPLACEMENT PARTS 7 10 9 10 7 8 1 2 3 4 5 6 7 11 12 13 14 ...
Страница 192: ...SECTION 7 REPLACEMENT PARTS 7 12 7 9 2 8 7 9 3 13 10 12 11 X5 1 4 5 6 2 3 7 8 9 TEE Detail ...
Страница 194: ...SECTION 7 REPLACEMENT PARTS 7 14 1 2 3 4 5 6 7 8 9 7 10 ...
Страница 196: ...SECTION 7 REPLACEMENT PARTS 7 16 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 198: ...SECTION 7 REPLACEMENT PARTS 7 18 1 2 3 4 5 6 7 7 5 Power Source Power Module ...
Страница 200: ...SECTION 7 REPLACEMENT PARTS 7 20 A A 1 2 3 4 5 6 7 8 Section A A ...
Страница 202: ...SECTION 7 REPLACEMENT PARTS 7 22 1 2 3 4 5 6 7 ...
Страница 204: ...SECTION 7 REPLACEMENT PARTS 7 24 1 2 3 4 5 6 7 9 8 10 11 12 13 14 15 16 17 18 19 19 21 22 21 23 24 21 25 26 20 10 27 ...
Страница 208: ...SECTION 7 REPLACEMENT PARTS 7 28 B B Section B B C C Section C C 1 2 3 4 5 6 7 8 ...
Страница 210: ...SECTION 7 REPLACEMENT PARTS 7 30 1 2 3 4 5 ...
Страница 224: ...SECTION 7 REPLACEMENT PARTS 7 44 Notes ...
Страница 225: ......