50
sectIon 6
trouBleshootIng
problem
possible cause
action
LED 6 – (red) Right Over Cur-
rent
note:
If operation at 400A or less is
possible, then the LEFT side is
not working.
Output current of the right side exceeds
300A because of operating the power source
over 600A.
Turn the output current down to
400A
Cutting at over 400A with a faulty left side
(left side output = 0)
See faulty left or right side
Right current transducer connector loose
or unplugged. PCB loose.
Secure connections
Loose or unplugged connector at right
PWM/Drive Printed circuit board.
Secure connection
P2 at left of PWM / Drive PCB loose or un-
plugged.
Secure connection
Check voltage between P7-6 and P7-7. A
voltage in either polarity of greater than
0.01 V indicates a faulty right current trans-
ducer (TD2).
Replace right current transducer
(TD2)
Faulty PCB1
Replace PCB1 P/N 0558038287
Faulty right PWM / Drive PCB
Replace right PWM / Drive PCB P/N
0558038308
LED 9 – (red) Left Over Current
note:
If operation at 400A or less is
possible, then the Right side is
not working.
Output current of the left side exceeds 300A
because of operating the power source
over 600A.
Turn the output current down to
400A
Cutting at over 400A with a faulty right side
(right side output = 0)
See faulty right side
Left current transducer connector loose or
unplugged. PCB loose.
Secure connections
Loose or unplugged connector at left PWM
/ Drive Printed circuit board.
Secure connection
P2 at right of PWM / Drive PCB loose or
unplugged.
Secure connection
Check voltage between P7-2 and P7-3. A
voltage in either polarity of greater than
0.01 V indicates a faulty left current trans-
ducer (TD1).
Replace left current transducer (TD1)
Faulty PCB1
Replace PCB1 P/N 0558038287
Faulty left PWM / Drive PCB
Replace left PWM / Drive PCB P/N
0558038308
neVer attempt to power-up or operate the power source with any
gate / emitter IgBt plug disconnected from it’s pWM / gate Drive
Board. attempting to operate the power source with any open (un-
plugged) IgBt gate / emitter connector may damage the IgBt and
the plasma cutting torch.
cautIon
Содержание Precision Plasmarc EPP-600
Страница 1: ...EPP 600 Plasma Power Source Instruction Manual 0558006514 08 2010 ...
Страница 4: ...4 ...
Страница 28: ...28 section 3 installation 3 7 3 Water Cooler Interface Cables with Mating Power Source Connectors at Both Ends ...
Страница 42: ...42 section 4 operation ...
Страница 63: ...63 section 6 TROUBLESHOOTING 80 ...
Страница 70: ...70 section 7 replacement parts ...
Страница 71: ...71 section 7 replacement parts ...
Страница 72: ...72 section 7 replacement parts ...
Страница 73: ...73 section 7 replacement parts ...
Страница 74: ...74 section 7 replacement parts ...
Страница 75: ...75 section 7 replacement parts EPP 400 Only 2 Places EPP 600 Only 2 Places ...
Страница 76: ...76 section 7 replacement parts ...
Страница 77: ...77 section 7 replacement parts 49 ...
Страница 78: ...78 section 7 replacement parts ...
Страница 79: ...79 section 7 replacement parts ...
Страница 80: ...80 section 7 replacement parts ...
Страница 81: ...81 section 7 replacement parts 35751Y 35752Y 0558006169 ...
Страница 82: ...82 section 7 replacement parts 17280215 R10 11 Resistor 1 5K OHMS 100W R28 31 951198 L3 FERRITE CORE ...
Страница 83: ...83 section 7 replacement parts ...
Страница 84: ...84 section 7 replacement parts ...
Страница 85: ...85 section 7 replacement parts ...
Страница 86: ...86 section 7 replacement parts 0558954035 ...
Страница 87: ...87 section 7 replacement parts 4600610 3 62 W ...
Страница 88: ...88 notes ...