ELECTrIC SHOCK CAN KILL! Precaution-
ary measures should be taken to provide
maximum protection against electrical
shock. Be sure that all power is off by
opening the line (wall) disconnect switch
and by unplugging the power cord to the
unit when connections are made inside of
the power source.
2.5
PrIMArY ELECTrICAL INPUT CONNECTIONS -
MECHANIZED PLASMA CUTTING PACKAGE
The PowerCut-1250 / 1500 consoles are equipped with approximately 10-ft. of
4-conductor input power cable for 3-phase connection. If single-phase connection
is desired, tape back the red (lt. blue) wire on the input power cable. Connect the
single-phase input to the white and black wires only. When operating this machine
from a single-phase source, it must be connected to a dedicated 100 Amp feed.
Due to the higher input current requirements, the duty cycle of the machine is
lower than in three-phase operation.
Connect your air supply to the inlet connection of the filter-regulator.
CUSTOMER FUSED LINE DISCONNECT SWITCH
(See Table 2.3 and WARNING in regards to
chassis ground in Section 2.5.)
PRIMARY INPUT
POWER CABLE
Prefiltered DRY AIR SUPPLY (Customer Supplied)
(90 to 150 psig max)
(6.2 to 10.3 bars max)
NUMBER
PIN
CONNECTION
8
H
Voltage Divider (-)
3
C
Voltage Divider (+)
9
I
Arc On signal from PS
7
G
to CNC, Relay Closing
14
N
Start signal from CNC
13
M
to PS, Relay Closing
figure 2-1. Input Connections
Red (Lt Blue) NOT USED ON SINGLE PHASE
White (Brown)
Black (Black)
Green (Yellow/Green)
SECTION 2
INSTALLATION
P/N 57002249
To CNC machine
H
I
G
N
M
C