52
section 6
troubleshootinG
6.4.4 procedure for verifying calibration of digital meters.
Voltmeter
1. Connect a digital meter known to be calibrated to the positive and negative output bus bars.
2. Compare the power source voltmeter reading to the calibrated meter reading. Readings should match within
±0.75%.
Ammeter
1. External to the power source, connect a precision shunt in series with the work lead(s). The best shunt is one with a
value of 100 micro-ohms (50mV / 500A or 100mV / 1000A) and a calibrated tolerance of 0.25%.
2. Use a calibrated 4 ½ digit meter to measure the output of the shunt. The amperage indicated with the external shunt
and meter should match power source ammeter to within 0.75%.
6.5 control circuit interface using J1, J4 and J6 connectors
Interface to the EPP-601 control circuitry is made with connectors J1, J4 and J6 on the front panel. J1 has 24 conductors, J4
has 2 and J6 has 10.
J1-P and J1-G provide access to the galvanically isolated transistor output signal indicating an “Arc On” condition. See
Subsection 6.8, Arc Current Detector Circuits. J1-L and J1-J are the inputs for the remote Voltage Reference Signal that
commands the EPP-601 output current Subsection 6.9, Current Control Pot & Remote Vref. J1-R and J1-Z supply 115V AC for
remote controls. See Subsection 6.6, Auxiliary Main Contactor (K3 and K33) & Solid State Contactor Circuits and Subsection
6.10, Pilot Arc Hi/lo & Cut/mark Circuits.
J1-E and J1-F are the input connections for the Emergency Stop function. For Emergency Stop to operate, the Jumper
between TB8-18 and TB8-19 must be removed.
J1-S is the input to K8 that parallels S1 switch contact. When 115V AC from J1-R is fed into J1-S, K8 activates placing the Pilot
Arc in High.
J4-A and J4-B are from an isolated contact on the emergency stop (E-stop) switch. This signal can be used by the plasma
control to indicate the state of the E-stop switch on the power source.
Cut / Mark selection: The power source defaults to Cutting mode when there is no signal fed into J1-C. When 115V AC from
J1-R is fed into J1-C, K11 is activated placing the EPP-601 in the Marking mode. For more details concerning the operation
of K11 and the Cut / Mark modes, refer to Subsection 6.10, High / Low Cut Current Modes and Mark Mode.
High / Low current ranges: The power source defaults to low cutting current range (35-100A) when no signal is fed into
J1-T. High range (50A to maximum current rating) is selected whenever 115VAC is fed into J1-T by connecting J1-R to J1-T.
J6 connects to the water cooler. J6-A and J6-B are 115VAC hot and neutral respectively. This 115VAC activates the contac-
tor for the pump. J6-C and J6-D connect to the flow switch. The flow switch is closed when coolant is flowing. J6-E and
J6-H connect to the coolant level switch. The switch is closed when the coolant reservoir contains sufficient coolant and
it is open when the reservoir is low.
Содержание Plasmarc EPP-601
Страница 1: ...EPP 601 Plasmarc RU 0558007979 06 2012...
Страница 2: ...52 529...
Страница 3: ......
Страница 4: ...4...
Страница 7: ...7 1 1 0 ESAB 1 B 2 3 4 5 IP 12 60 IP 23S 15 15...
Страница 8: ...8 1...
Страница 10: ...10 2 2 3 850 1143 mm 45 00 946 mm 37 25 1022 mm 40 25...
Страница 11: ...11 3 3 1 3 2 3 3 1 EPP 601...
Страница 12: ...12 3 3 4 3 4 1 EPP 601 3 I U x I x 0 68 U 2 2 EPP 601...
Страница 13: ...13 2 2 3 4 2 EPP 601 12 7 1 EPP 601 2 3 4 5 6 3 4 3 1 3 2 1 2 3 3 TB4 TB6...
Страница 14: ...14 3 5 3 5 1 600 4 0 AWG 400 600 100 4 0 AWG 600 100 3 3 5 2 1 2 3 UL 4 1...
Страница 15: ...15 3 EPP 600 3 6 100 100 600 4 0 AWG 600 14 AWG EPP 601 600 100 4 0 AWG 600 600 4 0 AWG...
Страница 19: ...19 3 3 7 24 8 3 7 1 4 647032...
Страница 20: ...20 3 4 3 7 2 647032 2010549 3 7 3 647257 2062105...
Страница 21: ...21 4 4 1 2 H 3 T1 300 375 300U120 0 0 10 0 I U x 80 High S T T T L1 L2 T T1 T1 425 250 R R EPP 601...
Страница 29: ...29 4 4 4 EPP 601 5 A 50 800 2 2 I 80 U I 10 U 800 I 80 U I 10 U...
Страница 31: ...31 4 4 4 4 38 4 4 5 PCB1 7 50 800 250 800 1200 90 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 SW1 SW2...
Страница 62: ...notes...