4 INSTALLATION
0460 157 301
- 11 -
© ESAB AB 2018
4.3
Mains power supply
Check that the unit is connected to the correct mains power supply
voltage, and that it is protected by the correct fuse sizes.
A protective earth connection must be made, in accordance with
regulations.
Rating plate with supply connection data.
Recommended fuse sizes and minimum cable areas
Tig 4300iw AC/DC
TIG
MMA
Mains voltage
400 V 3~ 50 Hz
400 V 3~ 50 Hz
Mains cable area,
mm
2
4G4
4G4
Phase current,
I
1eff
16.9 A
21.9 A
Fuse
Anti-surge
Type C MCB
20 A
20 A
20 A
25 A
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with
Swedish regulations. For other regions, supply cables must be suitable for the
application and meet local and national regulations.