![ESAB Origo Mig L305 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/esab/origo-mig-l305/origo-mig-l305_instruction-manual_2425115013.webp)
4 INSTALLATION
0349 301 124
- 13 -
© ESAB AB 2017
L405
3~ 50 Hz
3~ 50/60 Hz 3~ 50 Hz
3~ 60 Hz
3~ 60 Hz
at 100% duty cycle
28
16
13
28
14
at 60% duty cycle
42
24
19
41
21
at 50% duty cycle
45
28
20
45
22
Cable area mm
2
4 x 6
4 x 2.5
4 x 2.5
4 x 6
4 x 2.5
Fuse, slow A
25
20
20
25
20
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with
Swedish regulations. For other regions, supply cables must be suitable for the
application and meet local and national regulations.