© ESAB AB 2005
- 9 -
bm47d1ea
5.1
Connections and control devices
1
Connection for welding current from power
source, (OKC)
8
Safety contact switch
2
Connection for shielding gas
9
Connection for welding gun
3
Connection for control cable from power
source
10
Toggle switch for gas flushing / wire
inching
4
Connection RED, for coolant to power
source (cooling unit)
11
Toggle switch for 2 stroke/ 4 stroke
5
Connection BLUE, for coolant from power
source (cooling unit)
12
Display
6
Connection RED, for coolant from welding
gun
13
Knob for setting the voltage**
7
Connection BLUE, with ELP* for coolant to
the welding gun
14
Knob for setting wire feed speed
Note! Display (digital instrument) and coolant connections only available on certain models.
* ELP = ESAB Logic Pump, see point
5.2
.
** Voltage regulation from the wire feed unit does not function with step regulated power sources.
5.2
Function explanations
Water connection
The wire feed unit with water connection is equipped with a detection system
ELP
(
E
SAB
L
ogic
P
ump) which checks that the water hoses are connected. When
connecting a water-cooled welding gun, the water pump starts.
Detection only works with power sources that are equipped with ELP.
Strain relief
Hook the strain relief onto the hook on the rear side of the feeder unit and the
connection cable.