-- 8 --
bm36d1ea
6.1
Connections and control devices
1
Knob for setting burnback time
7
Connection for welding gun
2
Switch for creep start OFF / ON
8
Connection for welding current from power
source, (OKC)
3
Knob for setting wire feed speed.
9
Connection for control cable from power
source
4
Switch for 2--stroke / 4--stroke
10
Connection RED for cooling water to po-
wer source (cooling unit)
5
Connection BLUE, with ELP* for cooling
water to the welding gun
11
Connection BLUE for cooling water from
power source (cooling unit)
6
Connection RED for cooling water from
welding gun
12
Connection for shielding gas
NOTE! Cooling water connections only available on certain models.
* ELP = ESAB Logic Pump, see point 6.2.
6.2
Water connection
When connecting a water--cooled welding gun, the power source’s main power
supply switch must be in the Off position and the cooling unit switch must be in
position “ELP/0”.
The wire feed unit with water connection is equipped with a detection system
ELP
(
E
SAB
L
ogic
P
ump) which checks that the water hoses are connected. When
connecting a water--cooled welding gun, the water pump starts.
Detection only works with power sources that are equipped with ELP.
GB