2) DESCRIPTION
2.1) General description
The
wire feeders are designed for semi-automatic MIG/MAG welding with solid wires,
cored wires and aluminium in services of average and heavy production.
They have a progressive wire mechanism of 4 feed rollers and an electronic control system. They can be
installed on the power source, hanged on the workplace with appropriate hangers or on a wheel kit to move
it around the workplace (optional).
Origo™ Feed 354
Origo Feed 354 P3
22
3) TECHNICAL CHARACTERISTICS
TABLE 3.1
Power supply (V - Hz)
Wire feed speed (m/mm)
Wire diameter (mm)
Solid steel
Cored wire
Aluminium
Welding gun connection
Digital voltmeter/ampermeter
2/4 stroke
Voltage setting
Manual feeding
Bobbin cover
Burnback (sec)
Dimensions (W x L x H) (mm)
Weight (Kg)
42-50/60
1.5 - 29.0
0.8 - 1.6
1.2 - 2.4
1.0 - 1.2
Euro-conector
Yes
Yes
Yes
Yes
Optional
0 - 0.5
270 x 550 x 340 (with bobbin cover)
270 x 660 x 415 (without bobbin cover)
17.6
270 x 610 x 340 (with bobbin cover) from serial number: A11350002
270 x 720 x 415 (without bobbin cover) from serial number: A11350002
4) CONTROLS
4.1) Front panel
4.2) Side console
2 stroke
5) Burnback - Burnback time is a delay between the time when the wire starts to brake until the time when
the power source switches off the welding voltage.Too short burnback time results in a long wire stickout
after completion of welding, with a risk of the wire being caught in the solidifying weld pool. Too long a
burnback time results in a shorter stickout, with increased risk of the arc striking back to the contact tip.
6) 2/4 Stroke - With
, wire feed starts when the trigger switch is pressed in and ends when it is
released.
1) Knob for setting wire feed speed.
2) Knob for setting the voltage.
3) Digital voltmeter/ amperimeter. To display the welding voltage and current. After the welding it maintains
the set values shown on the display.
4) Connection for welding gun.
With
, the gas flow starts when the trigger switch is pressed in and the wire feed starts
when it is released. The welding process continues until the switch is pressed in again, the wire feed
stops and when the switch is released the gas stops flowing.
4 stroke
Содержание Origo Feed 354 P3
Страница 15: ... página em branco Origo Feed 354 P3 15 ...
Страница 17: ... página em branco Origo Feed 354 P3 17 ...
Страница 18: ... página em branco Origo Feed 354 P3 18 ...
Страница 24: ...4 3 1 For equipments after the serial number A11350002 Origo Feed 354 P3 24 6 5 7 3 1 2 4 12 11 8 9 10 ...
Страница 35: ... blank page Origo Feed 354 P3 35 ...
Страница 36: ... blank page Origo Feed 354 P3 36 ...
Страница 42: ...4 3 1 Para los equipos a partir del número de série A11350002 Origo Feed 354 P3 42 6 5 7 3 1 2 4 12 11 8 9 10 ...
Страница 52: ... página en blanco Origo Feed 354 P3 52 ...
Страница 54: ... página en blanco Origo Feed 354 P3 54 ...
Страница 61: ...Origo Feed 354 P3 61 página en blanco ...